Tuned mass damper
A tuned mass damper, also known as a harmonic absorber or seismic damper, is a device mounted in structures to reduce the amplitude of mechanical vibrations. Their application can prevent discomfort, damage, or outright structural failure. They are frequently used in power transmission, automobiles, and buildings.
Principle
Tuned mass dampers stabilize against violent motion caused by harmonic vibration. A tuned damper reduces the vibration of a system with a comparatively lightweight component so that the worst-case vibrations are less intense. Roughly speaking, practical systems are tuned to either move the main mode away from a troubling excitation frequency, or to add damping to a resonance that is difficult or expensive to damp directly. An example of the latter is a crankshaft torsional damper. Mass dampers are frequently implemented with a frictional or hydraulic component that turns mechanical kinetic energy into heat, like an automotive shock absorber.Given a motor with mass m1 attached via motor mounts to the ground, the motor vibrates as it operates and the soft motor mounts act as a parallel spring and damper, k1 and c1. The force on the motor mounts is F0. In order to reduce the maximum force on the motor mounts as the motor operates over a range of speeds, a smaller mass, m2, is connected to m1 by a spring and a damper, k2 and c2. F1 is the effective force on the motor due to its operation.
The graph shows the effect of a tuned mass damper on a simple spring–mass–damper system, excited by vibrations with an amplitude of one unit of force applied to the main mass, m1. An important measure of performance is the ratio of the force on the motor mounts to the force vibrating the motor,. This assumes that the system is linear, so if the force on the motor were to double, so would the force on the motor mounts. The blue line represents the baseline system, with a maximum response of 9 units of force at around 9 units of frequency. The red line shows the effect of adding a tuned mass of 10% of the baseline mass. It has a maximum response of 5.5, at a frequency of 7. As a side effect, it also has a second normal mode and will vibrate somewhat more than the baseline system at frequencies below about 6 and above about 10.
The heights of the two peaks can be adjusted by changing the stiffness of the spring in the tuned mass damper. Changing the damping also changes the height of the peaks, in a complex fashion. The split between the two peaks can be changed by altering the mass of the damper.
of displacements in the system with and without the 10% tuned mass.
The Bode plot is more complex, showing the phase and magnitude of the motion of each mass, for the two cases, relative to F1.
In the plots at right, the black line shows the baseline response. Now considering m2 = , the blue line shows the motion of the damping mass and the red line shows the motion of the primary mass. The amplitude plot shows that at low frequencies, the damping mass resonates much more than the primary mass. The phase plot shows that at low frequencies, the two masses are in phase. As the frequency increases m2 moves out of phase with m1 until at around 9.5 Hz it is 180° out of phase with m1, maximizing the damping effect by maximizing the amplitude of x2 − x1, this maximizes the energy dissipated into c2 and simultaneously pulls on the primary mass in the same direction as the motor mounts.
Mass dampers in automobiles
Motorsport
The tuned mass damper was introduced as part of the suspension system by Renault, on its 2005 F1 car, at the 2005 Brazilian Grand Prix. The system was invented by Dr. Robin Tuluie, and it reportedly reduced lap times by 0.3 seconds: a phenomenal gain for a relatively simple device. It was deemed to be legal at first, and it was in use up to the 2006 German Grand Prix.At Hockenheim, the mass damper was deemed illegal by the FIA, because the mass was not rigidly attached to the chassis and, due to the influence it had on the pitch attitude of the car, which in turn significantly affected the gap under the car and hence the ground effects of the car, to be a movable aerodynamic device and hence illegally influencing the performance of the aerodynamics.
The Stewards of the meeting deemed it legal, but the FIA appealed against that decision. Two weeks later, the FIA International Court of Appeal deemed the mass damper illegal.
Production cars
Tuned mass dampers are widely used in production cars, typically on the crankshaft pulley to control torsional vibration and, more rarely, the bending modes of the crankshaft. They are also used on the driveline for gearwhine, and elsewhere for other noises or vibrations on the exhaust, body, suspension or anywhere else. Almost all modern cars will have one mass damper, and some may have ten or more.The usual design of damper on the crankshaft consists of a thin band of rubber between the hub of the pulley and the outer rim. This device, often called a harmonic damper, is located on the other end of the crankshaft opposite of where the flywheel and the transmission is. An alternative design is the centrifugal pendulum absorber which is used to reduce the internal combustion engine's torsional vibrations on a few modern cars.
All four wheels of the Citroën 2CV incorporated a tuned mass damper of very similar design to that used in the Renault F1 car, from the start of production in 1949 on all four wheels, before being removed from the rear and eventually the front wheels in the mid 1970s.
Mass dampers in spacecraft
One proposal to reduce vibration on NASA's Ares solid fuel booster was to use 16 tuned mass dampers as part of a design strategy to reduce peak loads from 6g to 0.25g, the TMDs being responsible for the reduction from 1g to 0.25g, the rest being done by conventional vibration isolators between the upper stages and the booster.Spin stabilized satellites have nutation development at specific frequencies. Eddy current nutation dampers have flown on spin stabilized satellites to reduce and stabilize nutation.
Dampers in power transmission lines
often have small barbell-shaped Stockbridge dampers hanging from the wires to reduce the high-frequency, low-amplitude oscillation termed flutter.Dampers in wind turbines
A standard tuned mass damper for wind turbines consists of an auxiliary mass which is attached to the main structure by means of springs and dashpot elements. The natural frequency of the tuned mass damper is basically defined by its spring constant and the damping ratio determined by the dashpot. The tuned parameter of the tuned mass damper enables the auxiliary mass to oscillate with a phase shift with respect to the motion of the structure. In a typical configuration an auxiliary mass hung below the nacelle of a wind turbine supported by dampers or friction plates.Dampers in buildings and related structures
Typically, the dampers are huge concrete blocks or steel bodies mounted in skyscrapers or other structures, and moved in opposition to the resonance frequency oscillations of the structure by means of springs, fluid or pendulums.Earthquakes
The seismic waves caused by an earthquake will make buildings sway and oscillate in various ways depending on the frequency and direction of ground motion, and the height and construction of the building. Seismic activity can cause excessive oscillations of the building which may lead to structural failure. To enhance the building's seismic performance, a proper building design is performed engaging various seismic vibration control technologies.As mentioned above, damping devices had been used in the aeronautics and automobile industries long before they were standard in mitigating seismic damage to buildings. In fact, the first specialized damping devices for earthquakes were not developed until late in 1950.
Mechanical human sources
Masses of people walking up and down stairs at once, or great numbers of people stomping in unison, can cause serious problems in large structures like stadiums if those structures lack damping measures.Wind
The force of wind against tall buildings can cause the top of skyscrapers to move more than a meter. This motion can be in the form of swaying or twisting, and can cause the upper floors of such buildings to move. Certain angles of wind and aerodynamic properties of a building can accentuate the movement and cause motion sickness in people. A TMD is usually tuned to a certain building's frequency to work efficiently. However, during their lifetimes, high-rise and slender buildings may experience natural frequency changes under wind speed, ambient temperatures and relative humidity variations, among other factors, which requires a robust TMD design.Examples of buildings and structures with tuned mass dampers
Canada
- One Wall Centre in Vancouver — employs tuned liquid column dampers, a unique form of tuned mass damper at the time of their installation.
- CN Tower in Toronto.
China
- Shanghai Tower in Shanghai, China is the second tallest building in the world.
- Shanghai World Financial Center in Shanghai, China
Germany
- Berlin Television Tower — tuned mass damper located in the spire.
- VLF transmitter DHO38 – cylindrical containers filled with granulate in the mast structure
India
- ATC Tower Delhi Airport in New Delhi, India — a 50-ton tuned mass damper installed just beneath the ATC floor at 90m.
- Statue of Unity in Gujarat, India – a 400-ton tuned mass damper located at the chest level of Sardar Patel statue.
Iran
- Tehran International Tower
Ireland
- Dublin Spire in Dublin, Ireland — designed with a tuned mass damper to ensure aerodynamic stability during a wind storm.
Japan
- Akashi Kaikyō Bridge, between Honshu and Shikoku in Japan, currently the world's longest suspension bridge, uses pendulums within its suspension towers as tuned mass dampers.
- Ribbon Chapel in Hiroshima, Japan uses a TMD to damp vibrations in two intertwined helical stairways.
- Tokyo Skytree
- Yokohama Landmark Tower
- Chiba Port Tower, Japan
Russia
- Sakhalin-I — An offshore drilling platform
Taiwan
- Taipei 101 skyscraper — Contains the world's largest and heaviest tuned mass dampers, at.
United Arab Emirates
- Burj al-Arab in Dubai — 11 tuned mass dampers.
- Burj Khalifa in Dubai
United Kingdom
- London Millennium Bridge — nicknamed 'The Wobbly Bridge' due to swaying under heavy foot traffic. Dampers were fitted in response.
- One Canada Square — Prior to the topping out of the Shard in 2012, this was the tallest building in the UK.
United States of America
- 432 Park Avenue in New York City
- Bally's to Bellagio, Bally's to Caesars Palace, and Treasure Island to The Venetian Pedestrian Bridges in Las Vegas
- Bloomberg Tower/731 Lexington in New York City
- Citigroup Center in New York City — Designed by William LeMessurier and completed in 1977, it was one of the first skyscrapers to use a tuned mass damper to reduce sway. Uses a concrete version.
- Comcast Center in Philadelphia — Contains the largest Tuned Liquid Column Damper in the world at 1,300 tons.
- Comcast Technology Center in Philadelphia — A set of five tuned dampers containing 125,000 gallons of water—about 500 tons—are located on the 57th floor between the hotel's rooms and lobby.
- Grand Canyon Skywalk, Arizona
- The Hancock Tower in Boston — A tuned mass damper was added to it after it was built making it the 1st building to use a tuned mass damper.
- One Madison in New York City
- One Rincon Hill South Tower, San Francisco — First building in California to have a liquid tuned mass damper
- Park Tower in Chicago — The first building in the United States to be designed with a tuned mass damper from the outset.
- Random House Tower — Uses two liquid filled dampers in New York City
- Theme Building at Los Angeles International Airport Los Angeles
- Trump World Tower in New York City