Incineration


Incineration is a waste treatment process that involves the combustion of organic substances contained in waste materials. Incineration and other high-temperature waste treatment systems are described as "thermal treatment". Incineration of waste materials converts the waste into ash, flue gas and heat. The ash is mostly formed by the inorganic constituents of the waste and may take the form of solid lumps or particulates carried by the flue gas. The flue gases must be cleaned of gaseous and particulate pollutants before they are dispersed into the atmosphere. In some cases, the heat generated by incineration can be used to generate electric power.
Incineration with energy recovery is one of several waste-to-energy technologies such as gasification, pyrolysis and anaerobic digestion. While incineration and gasification technologies are similar in principle, the energy produced from incineration is high-temperature heat whereas combustible gas is often the main energy product from gasification. Incineration and gasification may also be implemented without energy and materials recovery.
In several countries, there are still concerns from experts and local communities about the environmental effect of incinerators.
In some countries, incinerators built just a few decades ago often did not include a materials separation to remove hazardous, bulky or recyclable materials before combustion. These facilities tended to risk the health of the plant workers and the local environment due to inadequate levels of gas cleaning and combustion process control. Most of these facilities did not generate electricity.
Incinerators reduce the solid mass of the original waste by 80%–85% and the volume by 95%–96%, depending on composition and degree of recovery of materials such as metals from the ash for recycling. This means that while incineration does not completely replace landfilling, it significantly reduces the necessary volume for disposal. Garbage trucks often reduce the volume of waste in a built-in compressor before delivery to the incinerator. Alternatively, at landfills, the volume of the uncompressed garbage can be reduced by approximately 70% by using a stationary steel compressor, albeit with a significant energy cost. In many countries, simpler waste compaction is a common practice for compaction at landfills.
Incineration has particularly strong benefits for the treatment of certain waste types in niche areas such as clinical wastes and certain hazardous wastes where pathogens and toxins can be destroyed by high temperatures. Examples include chemical multi-product plants with diverse toxic or very toxic wastewater streams, which cannot be routed to a conventional wastewater treatment plant.
Waste combustion is particularly popular in countries such as Japan, Singapore and the Netherlands, where land is a scarce resource. Denmark and Sweden have been leaders by using the energy generated from incineration for more than a century, in localised combined heat and power facilities supporting district heating schemes. In 2005, waste incineration produced 4.8% of the electricity consumption and 13.7% of the total domestic heat consumption in Denmark. A number of other European countries rely heavily on incineration for handling municipal waste, in particular Luxembourg, the Netherlands, Germany, and France.

History

The first UK incinerators for waste disposal were built in Nottingham by Manlove, Alliott & Co. Ltd. in 1874 to a design patented by Alfred Fryer. They were originally known as destructors.
The first US incinerator was built in 1885 on Governors Island in New York, NY. The first facility in the Czech Republic was built in 1905 in Brno.

Technology

An incinerator is a furnace for burning waste. Modern incinerators include pollution mitigation equipment such as flue gas cleaning. There are various types of incinerator plant design: moving grate, fixed grate, rotary-kiln, and fluidised bed.

Burn pile

The burn pile is one of the simplest and earliest forms of waste disposal, essentially consisting of a mound of combustible materials piled on the open ground and set on fire.
Burn piles can and have spread uncontrolled fires, for example, if the wind blows burning material off the pile into surrounding combustible grasses or onto buildings. As interior structures of the pile are consumed, the pile can shift and collapse, spreading the burn area. Even in a situation of no wind, small lightweight ignited embers can lift off the pile via convection, and waft through the air into grasses or onto buildings, igniting them. Burn piles often do not result in full combustion of waste and therefore produce particulate pollution.

Burn barrel

The burn barrel is a somewhat more controlled form of private waste incineration, containing the burning material inside a metal barrel, with a metal grating over the exhaust. The barrel prevents the spread of burning material in windy conditions, and as the combustibles are reduced they can only settle down into the barrel. The exhaust grating helps to prevent the spread of burning embers. Typically steel drums are used as burn barrels, with air vent holes cut or drilled around the base for air intake. Over time, the very high heat of incineration causes the metal to oxidize and rust, and eventually the barrel itself is consumed by the heat and must be replaced.
The private burning of dry cellulosic/paper products is generally clean-burning, producing no visible smoke, but plastics in the household waste can cause private burning to create a public nuisance, generating acrid odors and fumes that make eyes burn and water. Most urban communities ban burn barrels and certain rural communities may have prohibitions on open burning, especially those home to many residents not familiar with this common rural practice.
in the United States, private rural household or farm waste incineration of small quantities was typically permitted so long as it is not a nuisance to others, does not pose a risk of fire such as in dry conditions, and the fire does not produce dense, noxious smoke. A handful of states, such as New York, Minnesota, and Wisconsin, have laws or regulations either banning or strictly regulating open burning due to health and nuisance effects. People intending to burn waste may be required to contact a state agency in advance to check current fire risk and conditions, and to alert officials of the controlled fire that will occur.

Moving grate

The typical incineration plant for municipal solid waste is a moving grate incinerator. The moving grate enables the movement of waste through the combustion chamber to be optimized to allow a more efficient and complete combustion. A single moving grate boiler can handle up to of waste per hour, and can operate 8,000 hours per year with only one scheduled stop for inspection and maintenance of about one month's duration. Moving grate incinerators are sometimes referred to as Municipal Solid Waste Incinerators.
The waste is introduced by a waste crane through the "throat" at one end of the grate, from where it moves down over the descending grate to the ash pit in the other end. Here the ash is removed through a water lock.
Part of the combustion air is supplied through the grate from below. This air flow also has the purpose of cooling the grate itself. Cooling is important for the mechanical strength of the grate, and many moving grates are also water-cooled internally.
Secondary combustion air is supplied into the boiler at high speed through nozzles over the grate. It facilitates complete combustion of the flue gases by introducing turbulence for better mixing and by ensuring a surplus of oxygen. In multiple/stepped hearth incinerators, the secondary combustion air is introduced in a separate chamber downstream the primary combustion chamber.
According to the European Waste Incineration Directive, incineration plants must be designed to ensure that the flue gases reach a temperature of at least for 2 seconds in order to ensure proper breakdown of toxic organic substances. In order to comply with this at all times, it is required to install backup auxiliary burners, which are fired into the boiler in case the heating value of the waste becomes too low to reach this temperature alone.
The flue gases are then cooled in the superheaters, where the heat is transferred to steam, heating the steam to typically at a pressure of for the electricity generation in the turbine. At this point, the flue gas has a temperature of around, and is passed to the [|flue gas cleaning system].
In Scandinavia, scheduled maintenance is always performed during summer, where the demand for district heating is low. Often, incineration plants consist of several separate 'boiler lines', so that waste can continue to be received at one boiler line while the others are undergoing maintenance, repair, or upgrading.

Fixed grate

The older and simpler kind of incinerator was a brick-lined cell with a fixed metal grate over a lower ash pit, with one opening in the top or side for loading and another opening in the side for removing incombustible solids called clinkers. Many small incinerators formerly found in apartment houses have now been replaced by waste compactors.

Rotary-kiln

The rotary-kiln incinerator is used by municipalities and by large industrial plants.
This design of incinerator has two chambers: a primary chamber and secondary chamber. The primary chamber in a rotary kiln incinerator consists of an inclined refractory lined cylindrical tube. The inner refractory lining serves as sacrificial layer to protect the kiln structure. This refractory layer needs to be replaced from time to time. Movement of the cylinder on its axis facilitates movement of waste. In the primary chamber, there is conversion of solid fraction to gases, through volatilization, destructive distillation and partial combustion reactions. The secondary chamber is necessary to complete gas phase combustion reactions.
The clinkers spill out at the end of the cylinder. A tall flue-gas stack, fan, or steam jet supplies the needed draft. Ash drops through the grate, but many particles are carried along with the hot gases. The particles and any combustible gases may be combusted in an "afterburner".

Fluidized bed

A strong airflow is forced through a sandbed. The air seeps through the sand until a point is reached where the sand particles separate to let the air through and mixing and churning occurs, thus a fluidized bed is created and fuel and waste can now be introduced. The sand with the pre-treated waste and/or fuel is kept suspended on pumped air currents and takes on a fluid-like character. The bed is thereby violently mixed and agitated keeping small inert particles and air in a fluid-like state. This allows all of the mass of waste, fuel and sand to be fully circulated through the furnace.

Specialized incinerator

Furniture factory sawdust incinerators need much attention as these have to handle resin powder and many flammable substances. Controlled combustion, burn back prevention systems are essential as dust when suspended resembles the fire catch phenomenon of any liquid petroleum gas.

Use of heat

The heat produced by an incinerator can be used to generate steam which may then be used to drive a turbine in order to produce electricity. The typical amount of net energy that can be produced per tonne municipal waste is about 2/3 MWh of electricity and 2 MWh of district heating. Thus, incinerating about per day of waste will produce about 400 MWh of electrical energy per day and 1200 MWh of district heating energy each day.

Pollution

Incineration has a number of outputs such as the ash and the emission to the atmosphere of flue gas. Before the flue gas cleaning system, if installed, the flue gases may contain particulate matter, heavy metals, dioxins, furans, sulfur dioxide, and hydrochloric acid. If plants have inadequate flue gas cleaning, these outputs may add a significant pollution component to stack emissions.
In a study from 1997, Delaware Solid Waste Authority found that, for same amount of produced energy, incineration plants emitted fewer particles, hydrocarbons and less SO2, HCl, CO and NOx than coal-fired power plants, but more than natural gas–fired power plants. According to Germany's Ministry of the Environment, waste incinerators reduce the amount of some atmospheric pollutants by substituting power produced by coal-fired plants with power from waste-fired plants.

Gaseous emissions

Dioxin and furans

The most publicized concerns about the incineration of municipal solid wastes involve the fear that it produces significant amounts of dioxin and furan emissions. Dioxins and furans are considered by many to be serious health hazards. The EPA announced in 2012 that the safe limit for human oral consumption is 0.7 picograms Toxic Equivalence per kilogram bodyweight per day, which works out to 17 billionths of a gram for a 150 lb person per year.
In 2005, the Ministry of the Environment of Germany, where there were 66 incinerators at that time, estimated that "...whereas in 1990 one third of all dioxin emissions in Germany came from incineration plants, for the year 2000 the figure was less than 1%. Chimneys and tiled stoves in private households alone discharge approximately 20 times more dioxin into the environment than incineration plants."
According to the United States Environmental Protection Agency, the combustion percentages of the total dioxin and furan inventory from all known and estimated sources in the U.S. for each type of incineration are as follows: 35.1% backyard barrels; 26.6% medical waste; 6.3% municipal wastewater treatment sludge; 5.9% municipal waste combustion; 2.9% industrial wood combustion. Thus, the controlled combustion of waste accounted for 41.7% of the total dioxin inventory.
In 1987, before the governmental regulations required the use of emission controls, there was a total of Toxic Equivalence of dioxin emissions from US municipal waste combustors. Today, the total emissions from the plants are TEQ annually, a reduction of 99%.
Backyard barrel burning of household and garden wastes, still allowed in some rural areas, generates of dioxins annually.
Studies conducted by the US-EPA demonstrated that one family using a burn barrel produced more emissions than an incineration plant disposing of of waste per day by 1997 and five times that by 2007 due to increased chemicals in household trash and decreased emissions by municipal incinerators using better technology.
The same researchers found that their original estimates for the burn barrel were high, and that the incineration plant used for comparison represented a theoretical 'clean' plant rather than any existing facility. Their later studies found that burn barrels produced a median of 24.95 nanograms TEQ per lb garbage burned, so that a family burning 5 lbs of trash per day, or 1825 lbs per year, produces a total of 0.0455 mg TEQ per year, and that the equivalent number of burn barrels for the of the 251 municipal waste combustors inventoried by the EPA in the U.S. in 2000, is 1,841,700, or on average, 7337 family burn barrels per municipal waste incinerator.
Most of the improvement in U.S. dioxin emissions has been for large-scale municipal waste incinerators. As of 2000, although small-scale incinerators processed only 9% of the total waste combusted, these produced 83% of the dioxins and furans emitted by municipal waste combustion.

Dioxin cracking methods and limitations

The breakdown of dioxin requires exposure of the molecular ring to a sufficiently high temperature so as to trigger thermal breakdown of the strong molecular bonds holding it together. Small pieces of fly ash may be somewhat thick, and too brief an exposure to high temperature may only degrade dioxin on the surface of the ash. For a large volume air chamber, too brief an exposure may also result in only some of the exhaust gases reaching the full breakdown temperature. For this reason there is also a time element to the temperature exposure to ensure heating completely through the thickness of the fly ash and the volume of waste gases.
There are trade-offs between increasing either the temperature or exposure time. Generally where the molecular breakdown temperature is higher, the exposure time for heating can be shorter, but excessively high temperatures can also cause wear and damage to other parts of the incineration equipment. Likewise the breakdown temperature can be lowered to some degree but then the exhaust gases would require a greater lingering period of perhaps several minutes, which would require large/long treatment chambers that take up a great deal of treatment plant space.
A side effect of breaking the strong molecular bonds of dioxin is the potential for breaking the bonds of nitrogen gas and oxygen gas in the supply air. As the exhaust flow cools, these highly reactive detached atoms spontaneously reform bonds into reactive oxides such as NOx in the flue gas, which can result in smog formation and acid rain if they were released directly into the local environment. These reactive oxides must be further neutralized with selective catalytic reduction or selective non-catalytic reduction.

Dioxin cracking in practice

The temperatures needed to break down dioxin are typically not reached when burning plastics outdoors in a burn barrel or garbage pit, causing high dioxin emissions as mentioned above. While plastic does usually burn in an open-air fire, the dioxins remain after combustion and either float off into the atmosphere, or may remain in the ash where it can be leached down into groundwater when rain falls on the ash pile. Fortunately, dioxin and furan compounds bond very strongly to solid surfaces and are not dissolved by water, so leaching processes are limited to the first few millimeters below the ash pile. The gas-phase dioxins can be substantially destroyed using catalysts, some of which can be present as part of the fabric filter bag structure.
Modern municipal incinerator designs include a high-temperature zone, where the flue gas is sustained at a temperature above for at least 2 seconds before it is cooled down. They are equipped with auxiliary heaters to ensure this at all times. These are often fueled by oil or natural gas, and are normally only active for a very small fraction of the time. Further, most modern incinerators utilize fabric filters which can capture dioxins present in or on solid particles.
For very small municipal incinerators, the required temperature for thermal breakdown of dioxin may be reached using a high-temperature electrical heating element, plus a selective catalytic reduction stage.
Although dioxins and furans may be destroyed by combustion, their reformation by a process known as 'de novo synthesis' as the emission gases cool is a probable source of the dioxins measured in emission stack tests from plants that have high combustion temperatures held at long residence times.

CO2

As for other complete combustion processes, nearly all of the carbon content in the waste is emitted as CO2 to the atmosphere. MSW contains approximately the same mass fraction of carbon as CO2 itself, so incineration of 1 ton of MSW produces approximately 1 ton of CO2.
If the waste was landfilled, 1 ton of MSW would produce approximately methane via the anaerobic decomposition of the biodegradable part of the waste. Since the global warming potential of methane is 34 and the weight of 62 cubic meters of methane at 25 degrees Celsius is 40.7 kg, this is equivalent to 1.38 ton of CO2, which is more than the 1 ton of CO2 which would have been produced by incineration. In some countries, large amounts of landfill gas are collected. Still the global warming potential of the landfill gas emitted to atmosphere is significant. In the US it was estimated that the global warming potential of the emitted landfill gas in 1999 was approximately 32% higher than the amount of CO2 that would have been emitted by incineration. Since this study, the global warming potential estimate for methane has been increased from 21 to 35, which alone would increase this estimate to almost the triple GWP effect compared to incineration of the same waste.
In addition, nearly all biodegradable waste has biological origin. This material has been formed by plants using atmospheric CO2 typically within the last growing season. If these plants are regrown the CO2 emitted from their combustion will be taken out from the atmosphere once more.
Such considerations are the main reason why several countries administrate incineration of biodegradable waste as renewable energy. The rest – mainly plastics and other oil and gas derived products – is generally treated as non-renewables.
Different results for the CO2 footprint of incineration can be reached with different assumptions. Local conditions can decrease the CO2 benefits of incineration.
The methodology and other assumptions may also influence the results significantly. For example, the methane emissions from landfills occurring at a later date may be neglected or given less weight, or biodegradable waste may not be considered CO2 neutral. A study by Eunomia Research and Consulting in 2008 on potential waste treatment technologies in London demonstrated that by applying several of these unusual assumptions the average existing incineration plants performed poorly for CO2 balance compared to the theoretical potential of other emerging waste treatment technologies.

Other emissions

Other gaseous emissions in the flue gas from incinerator furnaces include nitrogen oxides, sulfur dioxide, hydrochloric acid, heavy metals, and fine particles. Of the heavy metals, mercury is a major concern due to its toxicity and high volatility, as essentially all mercury in the municipal waste stream may exit in emissions if not removed by emission controls.
The steam content in the flue may produce visible fume from the stack, which can be perceived as a visual pollution. It may be avoided by decreasing the steam content by flue-gas condensation and reheating, or by increasing the flue gas exit temperature well above its dew point. Flue-gas condensation allows the latent heat of vaporization of the water to be recovered, subsequently increasing the thermal efficiency of the plant.

Flue-gas cleaning

The quantity of pollutants in the flue gas from incineration plants may or may not be reduced by several processes, depending on the plant.
Particulate is collected by particle filtration, most often electrostatic precipitators and/or baghouse filters. The latter are generally very efficient for collecting fine particles. In an investigation by the Ministry of the Environment of Denmark in 2006, the average particulate emissions per energy content of incinerated waste from 16 Danish incinerators were below 2.02 g/GJ. Detailed measurements of fine particles with sizes below 2.5 micrometres were performed on three of the incinerators: One incinerator equipped with an ESP for particle filtration emitted 5.3 g/GJ fine particles, while two incinerators equipped with baghouse filters emitted 0.002 and 0.013 g/GJ PM2.5. For ultra fine particles, the numbers were 4.889 g/GJ PM1.0 from the ESP plant, while emissions of 0.000 and 0.008 g/GJ PM1.0 were measured from the plants equipped with baghouse filters.
Acid gas scrubbers are used to remove hydrochloric acid, nitric acid, hydrofluoric acid, mercury, lead and other heavy metals. The efficiency of removal will depend on the specific equipment, the chemical composition of the waste, the design of the plant, the chemistry of reagents, and the ability of engineers to optimize these conditions, which may conflict for different pollutants. For example, mercury removal by wet scrubbers is considered coincidental and may be less than 50%. Basic scrubbers remove sulfur dioxide, forming gypsum by reaction with lime.
Waste water from scrubbers must subsequently pass through a waste water treatment plant.
Sulfur dioxide may also be removed by dry desulfurisation by injection limestone slurry into the flue gas before the particle filtration.
NOx is either reduced by catalytic reduction with ammonia in a catalytic converter or by a high-temperature reaction with ammonia in the furnace. Urea may be substituted for ammonia as the reducing reagent but must be supplied earlier in the process so that it can hydrolyze into ammonia. Substitution of urea can reduce costs and potential hazards associated with storage of anhydrous ammonia.
Heavy metals are often adsorbed on injected active carbon powder, which is collected by particle filtration.

Solid outputs

Incineration produces fly ash and bottom ash just as is the case when coal is combusted. The total amount of ash produced by municipal solid waste incineration ranges from 4 to 10% by volume and 15–20% by weight of the original quantity of waste, and the fly ash amounts to about 10–20% of the total ash. The fly ash, by far, constitutes more of a potential health hazard than does the bottom ash because the fly ash often contain high concentrations of heavy metals such as lead, cadmium, copper and zinc as well as small amounts of dioxins and furans. The bottom ash seldom contain significant levels of heavy metals. At present although some historic samples tested by the incinerator operators' group would meet the being ecotoxic criteria at present the EA say "we have agreed" to regard incinerator bottom ash as "non-hazardous" until the testing programme is complete.

Other pollution issues

pollution can be a problem with old-style incinerators, but odors and dust are extremely well controlled in newer incineration plants. They receive and store the waste in an enclosed area with a negative pressure with the airflow being routed through the boiler which prevents unpleasant odors from escaping into the atmosphere. However, not all plants are implemented this way, resulting in inconveniences in the locality.
An issue that affects community relationships is the increased road traffic of waste collection vehicles to transport municipal waste to the incinerator. Due to this reason, most incinerators are located in industrial areas. This problem can be avoided to an extent through the transport of waste by rail from transfer stations.

Debate

Use of incinerators for waste management is controversial. The debate over incinerators typically involves business interests, government regulators, environmental activists and local citizens who must weigh the economic appeal of local industrial activity with their concerns over health and environmental risk.
People and organizations professionally involved in this issue include the U.S. Environmental Protection Agency and a great many local and national air quality regulatory agencies worldwide.

Arguments for incineration

The history of municipal solid waste incineration is linked intimately to the history of landfills and other waste treatment technology. The merits of incineration are inevitably judged in relation to the alternatives available. Since the 1970s, recycling and other prevention measures have changed the context for such judgements. Since the 1990s alternative waste treatment technologies have been maturing and becoming viable.
Incineration is a key process in the treatment of hazardous wastes and clinical wastes. It is often imperative that medical waste be subjected to the high temperatures of incineration to destroy pathogens and toxic contamination it contains.

Incineration in North America

The first incinerator in the U.S. was built in 1885 on Governors Island in New York.
In 1949, Robert C. Ross founded one of the first hazardous waste management companies in the U.S. He began Robert Ross Industrial Disposal because he saw an opportunity to meet the hazardous waste management needs of companies in northern Ohio. In 1958, the company built one of the first hazardous waste incinerators in the U.S.
The first full-scale, municipally operated incineration facility in the U.S. was the Arnold O. Chantland Resource Recovery Plant built in 1975 in Ames, Iowa. The plant is still in operation and produces refuse-derived fuel that is sent to local power plants for fuel. The first commercially successful incineration plant in the U.S. was built in Saugus, Massachusetts, in October 1975 by Wheelabrator Technologies, and is still in operation today.
There are several environmental or waste management corporations that transport ultimately to an incinerator or cement kiln treatment center. Currently, there are three main businesses that incinerate waste: Clean Harbours, WTI-Heritage, and Ross Incineration Services. Clean Harbours has acquired many of the smaller, independently run facilities, accumulating 5–7 incinerators in the process across the U.S. WTI-Heritage has one incinerator, located in the southeastern corner of Ohio across the Ohio River from West Virginia.
Several old generation incinerators have been closed; of the 186 MSW incinerators in 1990, only 89 remained by 2007, and of the 6200 medical waste incinerators in 1988, only 115 remained in 2003.
No new incinerators were built between 1996 and 2007. The main reasons for lack of activity have been:
There has been renewed interest in incineration and other waste-to-energy technologies in the U.S. and Canada. In the U.S., incineration was granted qualification for renewable energy production tax credits in 2004. Projects to add capacity to existing plants are underway, and municipalities are once again evaluating the option of building incineration plants rather than continue landfilling municipal wastes. However, many of these projects have faced continued political opposition in spite of renewed arguments for the greenhouse gas benefits of incineration and improved air pollution control and ash recycling.

Incineration in Europe

In Europe, with the ban on landfilling untreated waste, scores of incinerators have been built in the last decade, with more under construction. Recently, a number of municipal governments have begun the process of contracting for the construction and operation of incinerators. In Europe, some of the electricity generated from waste is deemed to be from a 'Renewable Energy Source and is thus eligible for tax credits if privately operated. Also, some incinerators in Europe are equipped with waste recovery, allowing the reuse of ferrous and non-ferrous materials found in landfills. A prominent example is the AEB Waste Fired Power Plant.
In Sweden, about 50% of the generated waste is burned in waste-to-energy facilities, producing electricity and supplying local cities' district heating systems. The importance of waste in Sweden's electricity generation scheme is reflected on their 2,700,000 tons of waste imported per year to supply waste-to-energy facilities.

Incineration in the United Kingdom

The technology employed in the UK waste management industry has been greatly lagging behind that of Europe due to the wide availability of landfills. The Landfill Directive set down by the European Union led to the Government of the United Kingdom imposing waste legislation including the landfill tax and Landfill Allowance Trading Scheme. This legislation is designed to reduce the release of greenhouse gases produced by landfills through the use of alternative methods of waste treatment. It is the UK Government's position that incineration will play an increasingly large role in the treatment of municipal waste and supply of energy in the UK.
In 2008, plans for potential incinerator locations exists for approximately 100 sites. These have been interactively mapped by UK NGO's.
Under a new plan in June 2012, a DEFRA-backed grant scheme was set up to encourage the use of low-capacity incinerators on agricultural sites to improve their bio security.
A permit has recently been granted for what would be the UK's largest waste incinerator in the centre of the Cambridge – Milton Keynes – Oxford corridor, in Bedfordshire. Following the construction of a large incinerator at Greatmoor in Buckinghamshire, and plans to construct a further one near Bedford, the Cambridge – Milton Keynes – Oxford corridor will become a major incineration hub in the UK.

Incineration Units for emergency use

Emergency incineration systems exist for the urgent and biosecure disposal of animals and their by-products following a mass mortality or disease outbreak. An increase in regulation and enforcement from governments and institutions worldwide has been forced through public pressure and significant economic exposure.
Contagious animal disease has cost governments and industry $200 billion over 20 years to 2012 and is responsible for over 65% of infectious disease outbreaks worldwide in the past sixty years. One-third of global meat exports is affected by trade restrictions at any time and as such the focus of Governments, public bodies and commercial operators is on cleaner, safer and more robust methods of animal carcass disposal to contain and control disease.
Large-scale incineration systems are available from niche suppliers and are often bought by governments as a safety net in case of contagious outbreak. Many are mobile and can be quickly deployed to locations requiring biosecure disposal.

Small incinerator units

Small-scale incinerators exist for special purposes. For example, the small-scale incinerators are aimed for hygienically safe destruction of medical waste in developing countries. Small incinerators can be quickly deployed to remote areas where an outbreak has occurred to dispose of infected animals quickly and without the risk of cross contamination.

In popular media