Venturi effect


The Venturi effect is the reduction in fluid pressure that results when a fluid flows through a constricted section of a pipe. The Venturi effect is named after its discoverer, Giovanni Battista Venturi.

Background

In fluid dynamics, an incompressible fluid's velocity must increase as it passes through a constriction in accord with the principle of mass continuity, while its static pressure must decrease in accord with the principle of conservation of mechanical energy. Thus, any gain in kinetic energy a fluid may attain by its increased velocity through a constriction is balanced by a drop in pressure.
By measuring pressure, the flow rate can be determined, as in various flow measurement devices such as Venturi meters, Venturi nozzles and orifice plates.
Referring to the adjacent diagram, using Bernoulli's equation in the special case of steady, incompressible, inviscid flows along a streamline, the theoretical pressure drop at the constriction is given by:
where is the density of the fluid, is the fluid velocity where the pipe is wider, is the fluid velocity where the pipe is narrower.

Choked flow

The limiting case of the Venturi effect is when a fluid reaches the state of choked flow, where the fluid velocity approaches the local speed of sound. When a fluid system is in a state of choked flow, a further decrease in the downstream pressure environment will not lead to an increase in the mass flow rate. However, mass flow rate for a compressible fluid will increase with increased upstream pressure, which will increase the density of the fluid through the constriction. This is the principle of operation of a de Laval nozzle. Increasing source temperature will also increase the local sonic velocity, thus allowing for increased mass flow rate but only if the nozzle area is also increased to compensate for the resulting decrease in density.

Expansion of the section

The Bernoulli equation is invertible, and pressure should rise when a fluid slows down. Nevertheless, if there is an expansion of the tube section, turbulence will appear and the theorem will not hold. In all experimental Venturi tubes, the pressure in the entrance is compared to the pressure in the middle section; the output section is never compared with them.

Experimental apparatus

Venturi tubes

The simplest apparatus is a tubular setup known as a Venturi tube or simply a Venturi. Fluid flows through a length of pipe of varying diameter. To avoid undue aerodynamic drag, a Venturi tube typically has an entry cone of 30 degrees and an exit cone of 5 degrees.
Venturi tubes are often used in processes where permanent pressure loss is not tolerable and where maximum accuracy is needed in case of highly viscous liquids.

Orifice plate

Venturi tubes are more expensive to construct than simple orifice plates, and both function on the same basic principle. However, for any given differential pressure, orifice plates cause significantly more permanent energy loss.

Instrumentation and measurement

Both Venturis and orifice plates are used in industrial applications and in scientific laboratories for measuring the flow rate of liquids.

Flow rate

A Venturi can be used to measure the volumetric flow rate,, using Bernoulli's principle.
Since
then
A Venturi can also be used to mix a liquid with a gas. If a pump forces the liquid through a tube connected to a system consisting of a Venturi to increase the liquid speed, a short piece of tube with a small hole in it, and last a Venturi that decreases speed, the gas will be sucked in through the small hole because of changes in pressure. At the end of the system, a mixture of liquid and gas will appear. See aspirator and pressure head for discussion of this type of siphon.

Differential pressure

As fluid flows through a Venturi, the expansion and compression of the fluids cause the pressure inside the Venturi to change. This principle can be used in metrology for gauges calibrated for differential pressures. This type of pressure measurement may be more convenient, for example, to measure fuel or combustion pressures in jet or rocket engines.
The first large-scale Venturi meters to measure liquid flows were developed by Clemens Herschel who used them to measure small and large flows of water and wastewater beginning at the end of the 19th century. While working for the Holyoke Water Power Company, Herschel would develop the means for measuring these flows to determine the water power consumption of different mills on the Holyoke Canal System, first beginning development of the device in 1886, two years later he would describe his invention of the Venturi meter to William Unwin in a letter dated June 5, 1888.

Compensation for temperature, pressure, and mass

Fundamentally, pressure-based meters measure kinetic energy density. Bernoulli's equation relates this to mass density and volumetric flow,
where constant terms are absorbed into k. Using the definitions of density, molar concentration, and molar mass, one can also derive mass flow or molar flow,
However, measurements outside the design point must compensate for the effects of temperature, pressure, and molar mass on density and concentration. The ideal gas law is used to relate actual values to design values,
Substituting these two relations into the pressure-flow equations above yields the fully compensated flows,
Q, m, or n are easily isolated by dividing and taking the square root. Note that pressure-, temperature-, and mass-compensation is required for every flow, regardless of the end units or dimensions. Also we see the relations,

Examples

The Venturi effect may be observed or used in the following:

Machines