Purple-K, also known as PKP, is a dry-chemical fire suppression agent used in some dry chemicalfire extinguishers. It is the second most effective dry chemical in fighting class B fires after Monnex, and can be used against some energized electrical equipment fires. It has about 4–5 times more effectiveness against class B fires than carbon dioxide, and more than twice that of sodium bicarbonate. Some fire extinguishers are capable of operation in temperatures down to −54 °C or up to +49 °C. Dry chemical works by directly inhibiting the chemical chain reaction which forms one of the four sides of the fire tetrahedron. To a much smaller degree it also has a smothering effect by excluding oxygen from the fire. "Dry chemical" extinguishers, such as Purple-K, are different from "dry powder" extinguishers that are used to fight Class D flammable metal fires. Purple-K was developed by the United States Naval Research Laboratory in 1959, as an improvement over sodium bicarbonate for extinguishing oil and gasoline fires. It was named due to the characteristic lavender tint imparted to flames, owing to the potassium content.
Characteristics
Purple-K powder has an acrid taste and odor, is free-flowing, floating on most liquids, non-abrasive, does not wet with water and is compatible with most foam concentrates. It has violet color, to distinguish it from other dry agents. Its principal component is potassium bicarbonate, with addition of sodium bicarbonate, mica, Fuller's earth, amorphous silica, and is made hydrophobic by methyl hydrogen polysiloxane. Purple-K is normally non-toxic, but ingestion of large amount can cause alkalosis.
Uses
Purple-K is commonly used in oil refineries, airport ramps, service stations, military facilities, naval warships, power plants, and other places where large volumes of flammable liquids are handled. It is often paired with foam in twin agent systems, usually found fitted to airport fire appliances. Purple-K is used in many forms, from small handheld fire extinguishers to large mobile and stationary units, including fixed-nozzle piping systems. Cleanup of spent agent can be difficult, as it forms a residue when discharged. If the spent agent is dry it can be removed by suction, but when combined with water, hydrocarbons and other liquids, it forms a thick crusty scum that can be challenging to remove. Purple-K should never be mixed with phosphate-based fire suppression agents, as the resulting chemical reaction will destroy its efficiency.