Optical fiber connector


An optical fiber connector terminates the end of an optical fiber, and enables quicker connection and disconnection than splicing. The connectors mechanically couple and align the cores of fibers so light can pass. Better connectors lose very little light due to reflection or misalignment of the fibers. In all, about 100 different types of fiber optic connectors have been introduced to the market.

Application

Optical fiber connectors are used to join optical fibers where a connect/disconnect capability is required. Due to the polishing and tuning procedures that may be incorporated into optical connector manufacturing, connectors are often assembled onto optical fiber in a supplier's manufacturing facility. However, the assembly and polishing operations involved can be performed in the field, for example, to terminate long runs at a patch panel.
Optical fiber connectors are used in telephone exchanges, for customer premises wiring, and in outside plant applications to connect equipment and cables, or to cross-connect cables.
Most optical fiber connectors are spring-loaded, so the fiber faces are pressed together when the connectors are mated. The resulting glass-to-glass or plastic-to-plastic contact eliminates signal losses that would be caused by an air gap between the joined fibers.
Performance of optical fiber connectors can be quantified by insertion loss and return loss. Measurements of these parameters are now defined in IEC standard 61753-1. The standard gives five grades for insertion loss from A to D, and M for multimode. The other parameter is return loss, with grades from 1 to 5.
A variety of optical fiber connectors are available, but SC and LC connectors are the most common types of connectors on the market. Typical connectors are rated for 500–1,000 mating cycles. The main differences among types of connectors are dimensions and methods of mechanical coupling. Generally, organizations will standardize on one kind of connector, depending on what equipment they commonly use.
In many data center applications, small and multi-fiber connectors have replaced larger, older styles, allowing more fiber ports per unit of rack space.
Outside plant applications may require connectors be located underground, or on outdoor walls or utility poles. In such settings, protective enclosures are often used, and fall into two broad categories: hermetic and free-breathing. Hermetic cases prevent entry of moisture and air but, lacking ventilation, can become hot if exposed to sunlight or other sources of heat. Free-breathing enclosures, on the other hand, allow ventilation, but can also admit moisture, insects and airborne contaminants. Selection of the correct housing depends on the cable and connector type, the location, and environmental factors.

Types

Many types of optical connector have been developed at different times, and for different purposes. Many of them are summarized in the tables below.
Short nameLong formCoupling typeScrew threadFerrule diameterStandardTypical applicationsNotesImage
Avio Aviation Intermediate MaintenanceScrewAerospace and avionics
ADT-UNIScrew2.5 mmMeasurement equipment
DMIDiamond Micro InterfaceClipn/a2.5 mmPrinted circuit boards
LSH or Snap, with light and dust-capn/a2.5 mmIEC 61754-15Telecom, DWDM systems;
ECpush-pull typen/aIEC 1754-8Telecom and CATV networks
ELIOBayonetn/a2.5 mmABS1379PC or UPC
ESCONEnterprise Systems ConnectionSnap n/a2.5 mmIBM mainframe computers and peripherals
F072.5 mmJapanese Industrial Standard LAN, audio systems; for 200 μm fibers, simple field termination possible, mates with ST connectors
F-3000Snap, with light and dust-capn/a1.25 mmIEC 61754-20Fiber To The Home
FCFerrule Connector or
Fiber Channel
ScrewM8×0.752.5 mmIEC 61754-13Datacom, telecom, measurement equipment, single-mode lasers
FibergateSnap, with dust-capn/a1.25 mmBackplane connector
FJFiber-Jack or
Opti-Jack
Snap n/a2.5 mmBuilding wiring, wall outlets
Lucent Connector,
Little Connector, or
Local Connector
Snapn/a1.25 mmIEC 61754-20High-density connections, SFP and SFP+ transceivers, XFP transceivers
Lucxis1.25 mmARINC 801PC or APC configurations
LX-5Snap, with light- and dust-capn/aIEC 61754-23High-density connections; rarely used
M12-FODuplex screwM162.5 mmEN 61754-27, ISO/IEC 61754-27Machine, process and plant engineering. IP-67 dust and water resistant
MICSnapn/a2.5 mmFiber distributed data interface
or MTPMultiple-Fiber Push-On/Pull-offSnap n/a2.5×6.4 mmIEC-61754-7; EIA/TIA-604-5 SM or MM multi-fiber ribbon. Same ferrule as MT, but more easily reconnectable. Used for indoor cabling and device interconnections. MTP is a brand name for an improved connector, which intermates with MPO.
MTMechanical TransferSnap n/a2.5×6.4 mmPre-terminated cable assemblies; outdoor applications
Mechanical Transfer Registered Jack or
Media Termination - recommended jack
Snap n/a2.45×4.4 mmIEC 61754-18Duplex multimode connections
MUMiniature unitSnapn/a1.25 mmIEC 61754-6Common in Japan
Subscriber connector,
square connector or
standard connector
Snap n/a2.5 mmIEC 61754-4Datacom and telecom; GPON; EPON; GBIC; MADI
/
SC-Dual Contact/
SC-Quattro Contact
Snap n/a2.5 mmIEC 61754-4Datacom and telecom; GPON; EPON; GBIC
SMA 905
F-SMA I
Sub Miniature AScrew 1/4"-36 UNS 2B3.17 mmIEC 60874-2Industrial lasers, optical spectrometers, military; telecom multimode
SMA 906
F-SMA II
Sub Miniature AScrew1/4"-36 UNS 2BStepped; typ., then IEC 60874-2Industrial lasers, military; telecom multimode
SMCSub Miniature CSnapn/a2.5 mm
or BFOCStraight Tip or
Bayonet Fiber Optic Connector
Bayonetn/a2.5 mmIEC 61754-2Datacom
TOSLINKToshiba LinkSnapn/amost common is JIS F05Digital audio
VF-45Volition FiberSnapn/aNone - V-grooves as guidanceDatacom
1053 HDTVBroadcast connector interfacePush-pull couplingn/aIndustry-standard 1.25 mm diameter ceramic ferruleAudio & Data
V-PINV-SystemSnap Push-pull couplingn/aIndustrial and electric utility networking; multimode 200 μm, 400 μm, 1 mm, 2.2 mm fibers

Obsolete connectors

Contact

Modern connectors typically use a physical contact polish on the fiber and ferrule end. This is a slightly convex surface with the apex of the curve accurately centered on the fiber, so that when the connectors are mated the fiber cores come into direct contact with one another. Some manufacturers have several grades of polish quality, for example a regular FC connector may be designated FC/PC, while FC/SPC and FC/UPC may denote super and ultra polish qualities, respectively. Higher grades of polish give less insertion loss and lower back reflection.
Many connectors are available with the fiber end face polished at an angle to prevent light that reflects from the interface from traveling back up the fiber. Because of the angle, the reflected light does not stay in the fiber core but instead leaks out into the cladding. Angle-polished connectors should only be mated to other angle-polished connectors. The APC angle is normally 8 degrees, however, SC/APC also exists as 9 degrees in some countries. Mating to a non-angle polished connector causes very high insertion loss. Generally angle-polished connectors have higher insertion loss than good quality straight physical contact ones. "Ultra" quality connectors may achieve comparable back reflection to an angled connector when connected, but an angled connection maintains low back reflection even when the output end of the fiber is disconnected.
Angle-polished connections are distinguished visibly by the use of a green strain relief boot, or a green connector body. The parts are typically identified by adding "/APC" to the name. For example, an angled FC connector may be designated FC/APC, or merely FCA. Non-angled versions may be denoted FC/PC or with specialized designations such as FC/UPC or FCU to denote an "ultra" quality polish on the fiber end face. Two different versions of FC/APC exist: FC/APC-N and FC/APC-R. An FC/APC-N connector key will not fit into a FC/APC-R adapter key slot.

Mnemonics

MT-RJ connectors look like a miniature RJ-45 connector.
ST connectors refer to having a straight tip, as the sides of the ceramic tip are parallel—as opposed to the predecessor bi-conic connector which aligned as two nesting ice cream cones would.
SC is short for subscriber connector. SMA is short for subminiature assembly.

Field-mountable connectors

Field-mountable optical fiber connectors are used to join optical fiber jumper cables that contain one single-mode fiber. Field-mountable optical fiber connectors are used for field restoration work and to eliminate the need to stock jumper cords of various sizes.
These assemblies can be separated into two major categories: single-jointed connector assemblies and multiple-jointed connector assemblies. According to Telcordia GR-1081, a single-jointed connector assembly is a connector assembly where there is only one spot where two different fibers are joined together. This is the situation generally found when connector assemblies are made from factory-assembled optical fiber connector plugs. A multiple-jointed connector assembly is a connector assembly where there is more than one closely spaced connection joining different fibers together. An example of a multiple-jointed connector assembly is a connector assembly that uses the stub-fiber type of connector plug.

Attributes

Features of good connector design:
Glass fiber optic connector performance is affected both by the connector and by the glass fiber. Concentricity tolerances affect the fiber, fiber core, and connector body. The core optical index of refraction is also subject to variations. Stress in the polished fiber can cause excess return loss. The fiber can slide along its length in the connector. The shape of the connector tip may be incorrectly profiled during polishing. The connector manufacturer has little control over these factors, so in-service performance may well be below the manufacturer's specification.
Testing fiber optic connector assemblies falls into two general categories: factory testing and field testing.
Factory testing is sometimes statistical, for example, a process check. A profiling system may be used to ensure the overall polished shape is correct, and a good quality optical microscope to check for blemishes. Insertion loss and return loss performance is checked using specific reference conditions, against a reference-standard single-mode test lead, or using an encircled flux compliant source for multi-mode testing. Testing and rejection may represent a significant part of the overall manufacturing cost.
Field testing is usually simpler. A special hand-held optical microscope is used to check for dirt or blemishes. A power meter and light source or an optical loss test set is used to test end-to-end loss, and an optical time-domain reflectometer may be used to identify significant point losses or return losses.