Nyquist frequency


The Nyquist frequency is half of the sampling rate of a discrete signal processing system. It is named after electronic engineer Harry Nyquist. When the function domain is time, sample rates are usually expressed in samples per second, and the unit of Nyquist frequency is cycles per second. When the function domain is distance, as in an image sampling system, the sample rate might be dots per inch and the corresponding Nyquist frequency would be in cycles/inch.
Nyquist frequency should not be confused with Nyquist rate, which is the minimum sampling rate that satisfies the Nyquist sampling criterion for a given signal or family of signals. The Nyquist rate is twice the maximum component frequency of the function being sampled. For example, the Nyquist rate for sampling a sinusoid at frequency is, which means that at the rate it is being undersampled. Thus, Nyquist rate is a property of a continuous-time signal, whereas Nyquist frequency is a property of a discrete-time system.
In a typical application of sampling, one first chooses the highest frequency to be preserved and recreated, based on the expected content and desired fidelity. Then one inserts an anti-aliasing filter ahead of the sampler. Its job is to attenuate the frequencies above that limit. Finally, based on the characteristics of the filter, one chooses a sample-rate that will provide an acceptably small amount of aliasing.
In applications where the sample-rate is pre-determined, the filter is chosen based on the Nyquist frequency, rather than vice versa. For example, audio CDs have a sampling rate of 44100 samples/sec. The Nyquist frequency is therefore 22050 Hz. The anti-aliasing filter must adequately suppress any higher frequencies but negligibly affect the frequencies within the human hearing range. A filter that preserves 0–20 kHz is more than adequate for that.

Folding frequency

In this example, is the sampling rate, and is the corresponding Nyquist frequency. The black dot plotted at represents the amplitude and frequency of a sinusoidal function whose frequency is 60% of the sample-rate. The other three dots indicate the frequencies and amplitudes of three other sinusoids that would produce the same set of samples as the actual sinusoid that was sampled. Undersampling of the sinusoid at is what allows there to be a lower-frequency alias. If the true frequency were, there would still be aliases at 0.6, 1.4, 1.6, etc.
The red lines depict the paths of the 4 dots if we were to adjust the frequency and amplitude of the sinusoid along the solid red segment. No matter what function we choose to change the amplitude vs frequency, the graph will exhibit symmetry between 0 and This symmetry is commonly referred to as folding, and another name for is folding frequency..

Other meanings

Early uses of the term Nyquist frequency, such as those cited above, are all consistent with the definition presented in this article. Some later publications, including some respectable textbooks, call twice the signal bandwidth the Nyquist frequency; this is a distinctly minority usage, and the frequency at twice the signal bandwidth is otherwise commonly referred to as the Nyquist rate.