Nordex
Nordex SE is a European company that designs, sells and manufactures wind turbines. The company's headquarters is located in the German city of Rostock while management is situated in Hamburg. Production takes place in Rostock as well as in China and for a brief time in Jonesboro, Arkansas. The company was founded in 1985 in Give, Denmark. Since then the company steadily grew. In 1995 Nordex was the first company to mass-produce a 1 MW turbine booster.
Wind turbines
As of 2013, the third generation of Nordex wind turbines included two platforms, rated at 2.4 and 3.3 MW.In Europe, Africa and North America Nordex manufactures and sells the Gamma series, a product family comprising the N90/2500, the N100/2500 and the N117/2400. The N90/2500 is a turbine being developed for strong winds. The N100/2500 consists of two versions, Highspeed and Lowspeed, the first one for rather windy locations, the second for medium wind conditions. The N117/2400 was designed especially for low-wind regions. The hub height of the 2.4-2.5 MW windturbines reaches from 65 meters for the N90/2500 to 141 meters for the low wind version of the N117/2400.
Technical data 2.5MW Gamma classhttp://www.nordex-online.com/fileadmin/MEDIA/Gamma/Nordex_Gamma_en.pdf Nordex platform brochure Gamma-Generation
Parameter | N80 IEC1 | N90 IEC1 | N90 IEC2 | N100 IEC 2 | N100 IEC3 | N117/2400 IEC3 |
Rated Power | 2,500 | 2,500 | 2,500 | 2,500 | 2,500 | 2,400 |
Cut-in wind speed | 3 | 3 | 3 | 3 | 3 | 3 |
Cut-out wind speed | 25 | 25 | 25 | 25 | 25 | 20 |
Rotor diameter | 80 | 90 | 90 | 100 | 100 | 117 |
Swept area | 5,026 | 6,362 | 6,362 | 7,823 | 7,823 | 10,751 |
m2 per MW | 2,010 | 2,548 | 2,548 | 3,129 | 3,129 | 4,480 |
Revolutions per minute | 10.8-18.9 | 10.3-18.1 | 9.6-16.8 | 9.6-14.8 | 9.6-14.8 | 7.5-13.2 |
Overspeed control | Pitch | Pitch | Pitch | Pitch | Pitch | Pitch |
Gearbox | yes | yes | yes | yes | yes | yes |
Generator | double-fed asynchronous generator | double-fed asynchronous generator | double-fed asynchronous generator | double-fed asynchronous generator | double-fed asynchronous generator | double-fed asynchronous generator |
Grid frequency | 50/60 Hertz | 50/60 Hertz | 50/60 Hertz | 50/60 Hertz | 50/60 Hertz | 50/60 Hertz |
Hub height | 60 | 65/70/80 | 80/100 | 75/80/100 | 80/100/140 | 91/120/141 |