Mars Environmental Dynamics Analyzer


The Mars Environmental Dynamics Analyzer is an instrument on board the Mars 2020 Perseverance rover that will characterize the dust size and morphology, as well as surface weather. Specifically, the information obtained will help address future human exploration objectives, as dust sizes and shapes, daily weather report and information on the radiation and wind patterns on Mars, that are critical for proper design of in situ resource utilization systems. MEDA is a follow-on project from REMS, of the Curiosity rover mission. MEDA has an increased scope, with greater data collection on Mars dust which contributes to overall Mars program objectives and discovery goals.
The instrument suite is being developed and provided by the Spanish Astrobiology Center at the Spanish National Research Council in Madrid, Spain. The Principal Investigator is José Antonio Rodríguez Manfredi.

Overview

Dust dominates Mars' weather the way that water dominates Earth's weather. Martian weather cannot be predicted unless dust behavior is studied and understood in the weather context. MEDA is a suite of environmental sensors designed to record dust optical properties and six atmospheric parameters: wind speed/direction, pressure, relative humidity, air temperature, ground temperature, and radiation.
The technology used on MEDA was inherited from the REMS package operating on the Curiosity rover and the TWINS package on InSight lander. The sensors are located on the rover's mast and on the deck, front and interior of the rover's body. It records data whether the rover is active or not, at both day and night. The instruments will collect data for 5 minutes every 30 minutes.
ParameterPerformance/units
Mass
PowerMax 17 watts
Data return≈11 megabytes
Temperatureaccuracy: 5 K
resolution: 0.1 K
Relative humidityaccuracy of 10%
in the 200-323 K range
PressureRange: 1 to 1150 Pa
accuracy: 20 Pa
resolution: 0.5 Pa
Radiationeight upward looking photodiodes:

• 255 +/– 5 nm for the O3

• 295 +/– 5 nm for the O3

• 250–400 nm for total UV

• 450±40 nm for MastCam-Z cross-calibration

• 650 +/– 25 nm for SuperCam cross-calibration

880 +/–5 nm for MastCam-Z cross-calibration

• 950 +/– 50 nm for NIR

• one panchromatic filter
Windaccuracy: 2 m/sec
resolution: 0.5 m/sec

Meda components