Mainz Microtron


The Mainz Microtron, abbreviated MAMI,
is a microtron which provides a continuous wave, high intensity, polarized electron beam with an energy up to 1.6 GeV. MAMI is the core of an experimental facility for particle, nuclear and X-ray radiation physics at the Johannes Gutenberg University in Mainz. It is one of the largest campus-based accelerator facilities for basic research in Europe. The experiments at MAMI are performed by about 200 physicists of many countries organized in international collaborations.

Research goals

The scientific research at MAMI focusses on the investigation of the
structure and dynamics of hadrons, particles consisting of quarks and gluons
bound by the strong force.
The most important hadrons
are protons and neutrons, the basic constituents
of atomic nuclei and, therefore, the building blocks of ordinary matter.
Electrons and photons interact with the electric charges
and the magnetization of quarks inside a hadron in a relatively weak and
well understood way providing undistorted information about
basic hadronic properties like size, magnetic moments,
distribution of charge and magnetism, flavor structure, polarizabilities and
excitation spectrum.
At MAMI the full potential of electroweak probes is explored in an
energy region characteristic for the first hadronic excitations and with a
spatial resolution in the order of the typical hadron size of about 1 fm.

The MAMI accelerator

The MAMI accelerator consists of four cascaded
microtrons, an injector linac, a thermal source for unpolarized
electrons and a laser-driven source for electrons with 80% spin polarization.
The operation principle is based on the
continuous wave microtron technique. There the
beam is recirculated many times
through a normal-conduction linear accelerating structure
with a moderate energy gain per turn. Due to constant, homogenous magnetic bending
fields the length of the beam path is increasing
with energy after each turn. The magnetic fields, the radio-frequency
used to accelerate the electrons and the energy gain per turn
have to be adjusted to meet the microtron coherence condition, i.e. the
condition that the length of each path is an integer factor of
the rf wavelength.
This microtron scheme makes efficient use of the rf power and
the inherent strong longitudinal phase focussing guarantees
excellent beam quality and stability.

In each of the first 3 stages
the recirculation is archived by two homogeneous 180° bending magnets.
The electron tracks are reminiscent of the race track of an
antique arena which is the origin for the name "race-track-microtron ".
The third stage, MAMI-B, started operation in 1990 and delivered
a beam for experiments with energies up to 882 MeV and 100 A cw for more than
97800 h until the end of 2007. The quality of the beam is very high:
an energy spread of 30 keV and an emittance of 25 nm*rad is achieved
routinely. The bending magnets of MAMI-B
are approximately 5 m wide and weigh 450 t. At this
point the mechanical limit of the RTM concept has been reached, leaving
MAMI-B to be the biggest microtron in the world.
At the end of the 1990s, the demand for an energy increase up to about 1500 MeV arose. This was accomplished by adding a fourth accelerator stage. Adding another RTM was not possible because it would have required bending magnets of ~2200 tons each. Therefore, the technique was modified by splitting the 180°-dipoles into a system of symmetric pairs of 90°-dipoles, each forming an achromatic 180°
bending system with magnets of only 250 tons each. To compensate for the strong vertical defocusing due to the 45° pole-face inclination
between the magnets, these dipoles incorporate an appropriate field gradient normal to this pole edge. In this scheme
there are two non-dispersive sections which allow to install two linear accelerators. To meet the microtron coherence condition
within the confined space of existing experimental areas the acceleration frequency of one of these linacs is twice the MAMI-B frequency of 2.45 GHz.
The other linac still operates at 2.45 GHz for enhanced
longitudinal stability.
This special rf scheme gave rise to the name Harmonic Double-Sided Microtron .
MAMI-C is the worldwide first accelerator
using this concept.
The construction work started in 2000.
End of December 2006, within one day,
the first test beam was guided through all 43 recirculations and reached
the design energy of 1508 MeV. After only a few weeks of beam tests,
the first nuclear physics experiment was conducted in February 2007.
About 50% of the MAMI beam time in 2007 was used for 1.5 GeV
operation. All design parameters of the HDSM, including the max. current
of 100 µA, have been verified. End of 2009 an energy
of 1604 MeV was reached.
The mean availability of the beam for experiments is at a very
high level, a clear demonstration that the
HDSM scheme is as reliable and stable as the RTM cascade.

Experimental facilities

High-resolution electron scattering

The largest experimental hall of the MAMI accelerator complex houses
three high-resolution, focussing magnetic spectrometers operated by the .
The high momentum resolution together with the large acceptance in solid angle
and in momentum makes this setup ideal for
electron scattering in coincidence with hadron detection.
One of the spectrometers can be tilted up to an out-of-plane angle of 10°, allowing for out-of-plane kinematics.
A proton recoil polarimeter gives, in combination with the polarized MAMI beam and
a polarized helium-3 gas target, access to a broad variety of spin observables.
A fourth spectrometer, the response of nucleons to quasi-static electromagnetic fields can be studied. This response is described in terms of polarizabilities and their spatial distribution.
A list of recent publications can be found .

Photoabsorption experiments

The studies reactions induced by high-energy photons incident
on nucleons or nuclei. A beam of photons with known energy and flux
is produced via bremsstrahlung using a dedicated
tagging spectrometer provided by the University of Glasgow.
A polarized electron beam produces circularly polarized photons. Linearly
polarized photons can be obtained from coherent bremsstrahlung in an oriented crystal radiator.
The central part of the detector system is a hermetic calorimeter consisting
of the Crystal Ball detector in combination with the TAPS detector
in forward direction. For charged-particle tracking and identification
two layers of coaxial multi-wire proportional chambers and a barrel of 24 scintillation
counters surrounding the target are installed inside the cavity of the Crystal Ball sphere.
A frozen-spin target for polarized protons and deuterons is of particular importance for
studying spin degrees of freedom.
The main physics goals are:
A publication database can be found .

Single spin asymmetries in elastic electron scattering

The measures small asymmetries in the cross-section of elastic scattering
of polarized electrons off an unpolarized target, basically hydrogen or deuterium.
The momentum transfers achieved either in forward angle- or backward
angle-configuration of the detector vary between 0.1 GeV²/c² and 0.6 GeV²/c².
A high-power liquid hydrogen target of 10 cm or 20 cm length and a polarized electron beam of I = 20 µA lead
to luminosities in the order of The scattered electrons are measured by a total
absorbing, segmented lead fluoride calorimeter, which deals with event rates of about 100 MHz.
The degree of polarization of the electron beam is measured by a laser Compton backscatter
polarimeter simultaneously with to the main experiment.

There are two main physics goals:
A list of publications can be found here .

Brilliant X-ray radiation

The at MAMI develops brilliant novel radiation sources and explores their
potential for applications. The electromagnetic spectrum extends from the far-infrared into the
hard X-ray range. "Brilliant" means that a large number of photons is emitted as a sharp bundle
from a small spot. At MAMI, beam spots with a diameter down to the sub-micron
range are possible. The production mechanisms which have been explored include Smith-Purcell radiation in the
infrared and optical spectral range, undulator radiation in the soft X-ray range as well as
channeling radiation, parametric X-radiation and transition radiation in the hard X-ray range.
A list of publications can be found .

Further Information and Reading

Homepage of the at the Mainz University.