Linear filter


Linear filters process time-varying input signals to produce output signals, subject to the constraint of linearity. In most cases these linear filters are also time invariant in which case they can be analyzed exactly using LTI system theory revealing their transfer functions in the frequency domain and their impulse responses in the time domain. Real-time implementations of such linear signal processing filters in the time domain are inevitably causal, an additional constraint on their transfer functions. An analog electronic circuit consisting only of linear components will necessarily fall in this category, as will comparable mechanical systems or digital signal processing systems containing only linear elements. Since linear time-invariant filters can be completely characterized by their response to sinusoids of different frequencies, they are sometimes known as frequency filters.
Non real-time implementations of linear time-invariant filters need not be causal. Filters of more than one dimension are also used such as in Image processing. The general concept of linear filtering also extends into other fields and technologies such as statistics, data analysis, and mechanical engineering.

Impulse response and transfer function

A linear time-invariant filter can be uniquely specified by its impulse response h, and the output of any filter is mathematically expressed as the convolution of the input with that impulse response. The frequency response, given by the filter's transfer function, is an alternative characterization of the filter. Typical filter design goals are to realize a particular frequency response, that is, the magnitude of the transfer function ; the importance of the phase of the transfer function varies according to the application, inasmuch as the shape of a waveform can be distorted to a greater or lesser extent in the process of achieving a desired response in the frequency domain. The frequency response may be tailored to, for instance, eliminate unwanted frequency components from an input signal, or to limit an amplifier to signals within a particular band of frequencies.
The impulse response h of a linear time-invariant causal filter specifies the output that the filter would produce if it were to receive an input consisting of a single impulse at time 0. An "impulse" in a continuous time filter means a Dirac delta function; in a discrete time filter the Kronecker delta function would apply. The impulse response completely characterizes the response of any such filter, inasmuch as any possible input signal can be expressed as a combination of weighted delta functions. Multiplying the impulse response shifted in time according to the arrival of each of these delta functions by the amplitude of each delta function, and summing these responses together yields the output waveform.
Mathematically this is described as the convolution of a time-varying input signal x with the filter's impulse response h, defined as:
The first form is the continuous-time form, which describes mechanical and analog electronic systems, for instance. The second equation is a discrete-time version used, for example, by digital filters implemented in software, so-called digital signal processing. The impulse response h completely characterizes any linear time-invariant filter. The input x is said to be "convolved" with the impulse response h having a duration of time T.
Filter design consists of finding a possible transfer function that can be implemented within certain practical constraints dictated by the technology or desired complexity of the system, followed by a practical design that realizes that transfer function using the chosen technology. The complexity of a filter may be specified according to the order of the filter.
Among the time-domain filters we here consider, there are two general classes of filter transfer functions that can approximate a desired frequency response. Very different mathematical treatments apply to the design of filters termed infinite impulse response filters, characteristic of mechanical and analog electronics systems, and finite impulse response filters, which can be implemented by discrete time systems such as computers.

Infinite impulse response filters

Consider a physical system that acts as a linear filter, such as a system of springs and masses, or an analog electronic circuit that includes capacitors and/or inductors. When such a system is subject to an impulse it responds with an output waveform that lasts past the duration of the input, eventually decaying exponentially in one or another manner, but never completely settling to zero. Such a system is said to have an infinite impulse response. The convolution integral above extends over all time: T must be set to infinity.
For instance, consider a damped harmonic oscillator such as a pendulum, or a resonant L-C tank circuit. If the pendulum has been at rest and we were to strike it with a hammer, setting it in motion, it would swing back and forth, say, with an amplitude of 10 cm. After 10 minutes, say, the pendulum would still be swinging but the amplitude would have decreased to 5 cm, half of its original amplitude. After another 10 minutes its amplitude would be only 2.5 cm, then 1.25 cm, etc. However it would never come to a complete rest, and we therefore call that response to the impulse "infinite" in duration.
The complexity of such a system is specified by its order N. N is often a constraint on the design of a transfer function since it specifies the number of reactive components in an analog circuit; in a digital IIR filter the number of computations required is proportional to N.

Finite impulse response filters

A filter implemented in a computer program is a discrete-time system; a different set of mathematical concepts defines the behavior of such systems. Although a digital filter can be an IIR filter if the algorithm implementing it includes feedback, it is also possible to easily implement a filter whose impulse truly goes to zero after N time steps; this is called a finite impulse response filter.
For instance, suppose one has a filter that, when presented with an impulse in a time series:
outputs a series that responds to that impulse at time 0 until time 4, and has no further response, such as:
Although the impulse response has lasted 4 time steps after the input, starting at time 5 it has truly gone to zero. The extent of the impulse response is finite, and this would be classified as a fourth-order FIR filter.
The convolution integral above need only extend to the full duration of the impulse response T, or the order N in a discrete time filter.

Implementation issues

Classical analog filters are IIR filters, and classical filter theory centers on the determination of transfer functions given by low order rational functions, which can be synthesized using the same small number of reactive components. Using digital computers, on the other hand, both FIR and IIR filters are straightforward to implement in software.
A digital IIR filter can generally approximate a desired filter response using less computing power than a FIR filter, however this advantage is more often unneeded given the increasing power of digital processors. The ease of designing and characterizing FIR filters makes them preferable to the filter designer when ample computing power is available. Another advantage of FIR filters is that their impulse response can be made symmetric, which implies a response in the frequency domain that has zero phase at all frequencies, which is absolutely impossible with any IIR filter.

Frequency response

The frequency response or transfer function of a filter can be obtained if the impulse response is known, or directly through analysis using Laplace transforms, or in discrete-time systems the Z-transform. The frequency response also includes the phase as a function of frequency, however in many cases the phase response is of little or no interest. FIR filters can be made to have zero phase, but with IIR filters that is generally impossible. With most IIR transfer functions there are related transfer functions having a frequency response with the same magnitude but a different phase; in most cases the so-called minimum phase transfer function is preferred.
Filters in the time domain are most often requested to follow a specified frequency response. Then, a mathematical procedure finds a filter transfer function that can be realized, and approximates the desired response to within some criterion. Common filter response specifications are described as follows:
Meeting a frequency response requirement with an FIR filter uses relatively straightforward procedures. In the most basic form, the desired frequency response itself can be sampled with a resolution of and Fourier transformed to the time domain. This obtains the filter coefficients hi, which implements a zero phase FIR filter that matches the frequency response at the sampled frequencies used. To better match a desired response, must be reduced. However the duration of the filter's impulse response, and the number of terms that must be summed for each output value is given by where T is the sampling period of the discrete time system. Thus the complexity of a digital filter and the computing time involved, grows inversely with, placing a higher cost on filter functions that better approximate the desired behavior. For the same reason, filter functions whose critical response is at lower frequencies require a higher order, more computationally intensive FIR filter. An IIR filter can thus be much more efficient in such cases.
Elsewhere the reader may find further discussion of design methods for practical FIR filter design.

IIR transfer functions

Since classical analog filters are IIR filters, there has been a long history of studying the range of possible transfer functions implementing various of the above desired filter responses in continuous time systems. Using transforms it is possible to convert these continuous time frequency responses to ones that are implemented in discrete time, for use in digital IIR filters. The complexity of any such filter is given by the order N, which describes the order of the rational function describing the frequency response. The order N is of particular importance in analog filters, because an Nth order electronic filter requires N reactive elements to implement. If a filter is implemented using, for instance, biquad stages using op-amps, N/2 stages are needed. In a digital implementation, the number of computations performed per sample is proportional to N. Thus the mathematical problem is to obtain the best approximation to the desired response using a smaller N, as we shall now illustrate.
Below are the frequency responses of several standard filter functions that approximate a desired response, optimized according to some criterion. These are all fifth-order low-pass filters, designed for a cutoff frequency of.5 in normalized units. Frequency responses are shown for the Butterworth, Chebyshev, inverse Chebyshev, and elliptic filters.
As is clear from the image, the elliptic filter is sharper than the others, but at the expense of ripples in both its passband and stopband. The Butterworth filter has the poorest transition but has a more even response, avoiding ripples in either the passband or stopband. A Bessel filter has an even poorer transition in the frequency domain, but maintains the best phase fidelity of a waveform. Different applications emphasize different design requirements, leading to different choices among these optimizations, or requiring a filter of a higher order.

Example implementations

A popular circuit implementing a second order active R-C filter is the Sallen-Key design, whose schematic diagram is shown here. This topology can be adapted to produce low-pass, band-pass, and high pass filters.
An Nth order FIR filter can be implemented in a discrete time system using a computer program or specialized hardware in which the input signal is subject to N delay stages. The output of the filter is formed as the weighted sum of those delayed signals, as is depicted in the accompanying signal flow diagram. The response of the filter depends on the weighting coefficients denoted b0, b1,.... bN. For instance, if all of the coefficients were equal to unity, a so-called boxcar function, then it would implement a low-pass filter with a low frequency gain of N+1 and a frequency response given by the sinc function. Superior shapes for the frequency response can be obtained using coefficients derived from a more sophisticated design procedure.

Mathematics of filter design

describes linear time-invariant filters of all types. LTI filters can be completely described by their frequency response and phase response, the specification of which uniquely defines their impulse response, and vice versa. From a mathematical viewpoint, continuous-time IIR LTI filters may be described in terms of linear differential equations, and their impulse responses considered as Green's functions of the equation. Continuous-time LTI filters may also be described in terms of the Laplace transform of their impulse response, which allows all of the characteristics of the filter to be analyzed by considering the pattern of zeros and poles of their Laplace transform in the complex plane. Similarly, discrete-time LTI filters may be analyzed via the Z-transform of their impulse response.
Before the advent of computer filter synthesis tools, graphical tools such as Bode plots and Nyquist plots were extensively used as design tools. Even today, they are invaluable tools to understanding filter behavior. Reference books had extensive plots of frequency response, phase response, group delay, and impulse response for various types of filters, of various orders. They also contained tables of values showing how to implement such filters as RLC ladders - very useful when amplifying elements were expensive compared to passive components. Such a ladder can also be designed to have minimal sensitivity to component variation a property hard to evaluate without computer tools.
Many different analog filter designs have been developed, each trying to optimise some feature of the system response. For practical filters, a custom design is sometimes desirable, that can offer the best tradeoff between different design criteria, which may include component count and cost, as well as filter response characteristics.
These descriptions refer to the mathematical properties of the filter. These can be implemented as analog circuits, or as algorithms in digital signal processing systems.
Digital filters are much more flexible to synthesize and use than analog filters, where the constraints of the design permits their use. Notably, there is no need to consider component tolerances, and very high Q levels may be obtained.
FIR digital filters may be implemented by the direct convolution of the desired impulse response with the input signal.
They can easily be designed to give a matched filter for any arbitrary pulse shape.
IIR digital filters are often more difficult to design, due to problems including dynamic range issues, quantization noise and instability.
Typically digital IIR filters are designed as a series of digital biquad filters.
All low-pass second-order continuous-time filters have a transfer function given by
All band-pass second-order continuous-time filters have a transfer function given by
where