Kilowatt-hour


The kilowatt-hour is a unit of energy equal to 3600 kilojoules. The kilowatt-hour is commonly used as a billing unit for energy delivered to consumers by electric utilities.

Definition

The kilowatt-hour is a composite unit of energy equal to one kilowatt of power sustained for one hour. Expressed in the standard unit of energy in the International System of Units, the joule, it is equal to 3600 kilojoules.
The hour is a unit of time listed among the non-SI units accepted by the International Bureau of Weights and Measures for use with the SI. Its combination with the kilowatt, a standard SI unit, is therefore permitted within the standard.

Unit representations

A widely used symbolic representation of the kilowatt-hour is "kWh", from the unit symbols of its component units, kilowatt and hour. It is commonly used in commercial, educational, and scientific publications and in the media. It is also the usual unit representation in electrical power engineering. This common representation does not comply with the style guide of the International System of Units.
Other representations of the unit may be encountered:
Electrical energy is typically sold to consumers in kilowatt-hours. The cost of running an electrical device is calculated by multiplying the device's power consumption in kilowatts by the operating time in hours, and by the price per kilowatt-hour. The unit price of electricity charged by utility companies may depend on the customer's consumption profile over time. Prices vary considerably by locality. In the United States prices in different states can vary by a factor of three.
While smaller customer loads are usually billed only for energy, transmission services, and the rated capacity, larger consumers also pay for peak power consumption, the greatest power recorded in a fairly short time, such as 15 minutes. This compensates the power company for maintaining the infrastructure needed to provide peak power. These charges are billed as demand changes. Industrial users may also have extra charges according to the power factor of their load.
Major energy production or consumption is often expressed as terawatt-hours for a given period that is often a calendar year or financial year. A 365-day year equals 8,760 hours, so over a period of one year, power of one gigawatt equates to 8.76 terawatt-hours of energy. Conversely, one terawatt-hour is equal to a sustained power of about 114 megawatts for a period of one year.

Examples

An electric heater consuming 1000 watts, and operating for one hour uses one kilowatt-hour of energy. A television consuming 100 watts operating for 10 hours continuously uses one kilowatt-hour. A 40-watt electric appliance operating continuously for 25 hours uses one kilowatt-hour. In terms of human power, a healthy adult male manual laborer performs work equal to about one half of one kilowatt-hour over an eight-hour day.

Conversions

To convert a quantity measured in a unit in the left column to the units in the top row, multiply by the factor in the cell where the row and column intersect.
1 J = 1 kg⋅m2⋅s−2 =12.77778 × 10−42.77778 × 10−76.241 × 10180.239
1 Wh =3.6 × 10310.0012.247 × 1022859.8
1 kWh =3.6 × 1061,00012.247 × 10258.598 × 105
1 eV =1.602 × 10−194.45 × 10−234.45 × 10−2613.827 × 10−20
1 cal =4.21.163 × 10−31.163 × 10−62.613 × 10191
JouleWatt-hourKilowatt-hourElectronvoltCalorie

Watt-hour multiples

All the SI prefixes are commonly applied to the watt-hour: a kilowatt-hour is 1,000 Wh ; a megawatt-hour is 1 million Wh ; a milliwatt-hour is 1/1000 Wh and so on.
The kilowatt-hour is commonly used by electrical energy providers for purposes of billing, since the monthly energy consumption of a typical residential customer ranges from a few hundred to a few thousand kilowatt-hours. Megawatt-hours, gigawatt-hours, and terawatt-hours are often used for metering larger amounts of electrical energy to industrial customers and in power generation. The terawatt-hour and petawatt-hour units are large enough to conveniently express the annual electricity generation for whole countries and the world energy consumption.

Distinguishing between kilowatt-hours (energy) and kilowatts (power)

Energy is the work performed; and power is the rate of delivery of energy.
Energy is measured in joules, or watt seconds. Power is measured in watts, or joules per second.
For example, a battery stores energy. When the battery delivers its energy, it does so at a certain power, that is, the rate of delivery of the energy. The higher the power, the quicker the battery's stored energy is delivered. A higher power output will cause the battery's stored energy to be depleted in a shorter time period.

Annualized power

Electric energy production and consumption are sometimes reported on a yearly basis, in units such as megawatt-hours per year gigawatt-hours/year or terawatt-hours per year. These units have dimensions of energy divided by time and thus are units of power. They can be converted to SI power units by dividing by the number of hours in a year, about.
Thus, 1 GWh/yr ≈.

Misuse of watts per hour

Power units measure the rate of energy per unit time. Many compound units for various kinds of rates explicitly mention units of time: for example, miles per hour, kilometres per hour, dollars per hour. Kilowatt-hours are a product of power and time, not a rate of change of power with time.
Watts per hour is a unit of a change of power per hour, i.e. an acceleration in the delivery of energy. It is used to measure the daily variation of demand, or ramp-up behavior of power plants. For example, a power plant that reaches a power output of from in 15 minutes has a ramp-up rate of. Hydroelectric power plants have a very high ramp-up rate, which makes them particularly useful in peak load and emergency situations.
Other uses of terms such as watts per hour are likely to be errors.

Other use

By definition of the units, a consumption of 1 kWh/ is exactly equivalent to a resistance force of 36 N, an idea taken up by the von Kármán–Gabrielli diagram.

Other related energy units

Several other units related to kilowatt-hour are commonly used to indicate power or energy capacity or use in specific application areas.
Average annual power production or consumption can be expressed in kilowatt-hours per year. This is used with loads or output that vary during the year but that are similar in each year. For example, it is useful to compare the energy efficiency of household appliances whose power consumption varies with time or the season of the year. Another use case is to measure the energy produced by a distributed power source. One kilowatt-hour per year equals about 114.08 milliwatts applied constantly during one year.
The energy content of a battery is usually expressed indirectly by its capacity in ampere-hours; to convert ampere-hour to watt-hours, the ampere-hour value must be multiplied by the voltage of the power source. This value is approximate, since the battery voltage is not constant during its discharge, and because higher discharge rates reduce the total amount of energy that the battery can provide. In the case of devices that output a different voltage than the battery, it is the battery voltage that must be used to calculate rather than the device output. This results in a 500 mA USB device running for about 3.7 hours on a 2500 mAh battery, not five hours.
The Board of Trade unit is an obsolete UK synonym for kilowatt-hour. The term derives from the name of the Board of Trade which regulated the electricity industry until 1942 when the Ministry of Power took over.
In India, the kilowatt-hour is often simply called a Unit of energy. A million units, designated MU, is a gigawatt-hour and a BU is a terawatt-hour.