In electrical engineering, two conductors are said to be inductively coupled or magnetically coupled when they are configured such that a change in current through one wireinduces a voltage across the ends of the other wire through electromagnetic induction. A changing current through the first wire creates a changing magnetic field around it by Ampere's circuital law. The changing magnetic field induces an electromotive force in the second wire by Faraday's law of induction. The amount of inductive coupling between two conductors is measured by their mutual inductance. The coupling between two wires can be increased by winding them into coils and placing them close together on a common axis, so the magnetic field of one coil passes through the other coil. Coupling can also be increased by a magnetic core of a ferromagnetic material like iron or ferrite in the coils, which increases the magnetic flux. The two coils may be physically contained in a single unit, as in the primary and secondary windings of a transformer, or may be separated. Coupling may be intentional or unintentional. Unintentional inductive coupling can cause signals from one circuit to be induced into a nearby circuit, this is called cross-talk, and is a form of electromagnetic interference. An inductively coupled transponder consists of a solid statetransceiver chip connected to a large coil that functions as an antenna. When brought within the oscillating magnetic field of a reader unit, the transceiver is powered up by energy inductively coupled into its antenna and transfers data back to the reader unit inductively. Magnetic coupling between two magnets can also be used to mechanically transfer power without contact, as in the magnetic gear.
Uses
Inductive coupling is widely used throughout electrical technology; examples include:
Low-frequency induction can be a dangerous form of inductive coupling when it happens inadvertently. For example, if metal long-distance pipeline is installed along a right of wayin parallel with a high-voltage power line, the power line can induce current on the pipe. Since the pipe is a conductor, insulated by its protective coating from the earth, it acts as a secondary winding for a long, drawn out transformer whose primary winding is the power line. Voltages induced on the pipe are then a hazard to people operating valves or otherwise touching metal parts of the metal pipeline. Reducing low-frequency magnetic fields may be necessary when dealing with electronics, as sensitive circuits in close proximity to an instrument with a power transformer could begin to display 60Hz pickup. Twisted wires are an effective way of reducing the interference as signals induced in the successive twists cancel. Using magnetic shielding is also an effective way of reducing unwanted inductive coupling, though moving the source of the magnetic field away from sensitive electronics is the simplest solution if possible. Although induced currents can be harmful, they can also be helpful. Electrical distribution line engineers use inductive coupling to tap power for cameras on towers and at substations that allow remote monitoring of the facilities. Using this they can watch from anywhere and not need to worry about changing camera batteries or solar panel maintenance.