Electrode potential


Electrode potential, E, in chemistry or electrochemistry, according to an IUPAC definition, is the electromotive force of a cell built of two electrodes:
The SHE is defined to have a potential of 0 V, so the signed cell potential from the above setup is
The SHE is the anode and an electrode is a cathode
An electrode potential is strictly the potential difference developed at the interface between the electrode and the solution. It is common, for instance, to speak of the electrode potential of the M+/M redox couple. These potential differences are measured relative to the potential difference developed at a suitable reference electrode, which is conventionally the SHE; that is to say, E = -.

Origin and interpretation

Electrode potential appears at the interface between an electrode and electrolyte due to the transfer of charged species across the interface, specific adsorption of ions at the interface, and specific adsorption/orientation of polar molecules, including those of the solvent.
In a cell, there is an electrode potential for the cathode and an electrode potential for the anode. The difference between the two electrode potentials equals the cell potential:
The measured electrode potential may be either that at equilibrium on the working electrode, or a potential with a non-zero net reaction on the working electrode but zero net current, or a potential with a non-zero net current on the working electrode. Reversible potentials can be sometimes converted to the standard electrode potential for a given electroactive species by extrapolation of the measured values to the standard state.
The value of the electrode potential under non-equilibrium depends on the nature and composition of the contacting phases, and on the kinetics of electrode reactions at the interface.
An operational assumption for determinations of the electrode potentials with the standard hydrogen electrode involves this reference electrode with hydrogen ion in an ideal solution having is "zero potential at all temperatures" equivalently to standard enthalpy of formation of hydrogen ion is also "zero at all temperatures".

Measurement

The measurement is generally conducted using a three-electrode setup :
  1. working electrode,
  2. counter electrode,
  3. reference electrode.
In case of non-zero net current on the electrode, it is essential to minimize the ohmic IR-drop in the electrolyte, e.g., by positioning the reference electrode near the surface of the working electrode, or by using a supporting electrolyte of sufficiently high conductivity. The potential measurements are performed with the positive terminal of the electrometer connected to the working electrode and the negative terminal to the reference electrode.

Sign conventions

Historically, two conventions for sign for the electrode potential have formed:
  1. convention "Nernst–Lewis–Latimer",
  2. convention "Gibbs–Ostwald–Stockholm".
In 1953 in Stockholm IUPAC recognized that either of the conventions is permissible; however, it unanimously recommended that only the magnitude expressed according to the convention be called "the electrode potential". To avoid possible ambiguities, the electrode potential thus defined can also be referred to as Gibbs–Stockholm electrode potential. In both conventions, the standard hydrogen electrode is defined to have a potential of 0 V. Both conventions also agree on the sign of E for a half-cell reaction when it is written as a reduction.
The main difference between the two conventions is that upon reversing the direction of a half-cell reaction as written, according to the convention the sign of E also switches, whereas in the convention it does not. The logic behind switching the sign of E is to maintain the correct sign relationship with the Gibbs free energy change, given by Δ G = -nFE where n is the number of electrons involved and F is the Faraday constant. It is assumed that the half-reaction is balanced by the appropriate SHE half-reaction. Since Δ G switches sign when a reaction is written in reverse, so too, proponents of the convention argue, should the sign of E. Proponents of the convention argue that all reported electrode potentials should be consistent with the electrostatic sign of the relative potential difference.

Potential difference of a cell assembled of two electrodes

Potential of a cell assembled of two electrodes can be determined from the two individual electrode potentials using
or, equivalently,
This follows from the IUPAC definition of the electric potential difference of a galvanic cell, according to which the electric potential difference of a cell is the difference of the potentials of the electrodes on the right and the left of the galvanic cell. When ΔVcell is positive, then positive electrical charge flows through the cell from the left electrode to the right electrode.