Color rendering index
A color rendering index is a quantitative measure of the ability of a light source to reveal the colors of various objects faithfully in comparison with an ideal or natural light source. Light sources with a high CRI are desirable in color-critical applications such as neonatal care and art restoration. It is defined by the International Commission on Illumination as follows:
Color rendering: Effect of an illuminant on the color appearance of objects by conscious or subconscious comparison with their color appearance under a reference illuminant.
The CRI of a light source does not indicate the apparent color of the light source; that information is given by the correlated color temperature. The CRI is determined by the light source's spectrum. An incandescent lamp has a continuous spectrum, a fluorescent lamp has a discrete line spectrum; the incandescent lamp has the higher CRI.
The value often quoted as "CRI" on commercially available lighting products is properly called the CIE Ra value, "CRI" being a general term and CIE Ra being the international standard color rendering index.
Numerically, the highest possible CIE Ra value is 100 and would only be given to a source identical to standardized daylight or a black body, dropping to negative values for some light sources. Low-pressure sodium lighting has negative CRI; fluorescent lights range from about 50 for the basic types, up to about 98 for the best multi-phosphor type. Typical LEDs have a CRI of 80 or more, while some manufacturers claim that their LEDs have achieved CRI up to 98.
CIE Ra's ability to predict color appearance has been criticized in favor of measures based on color appearance models, such as CIECAM02 and for daylight simulators, the CIE Metamerism Index.
CRI is not a good indicator for use in visual assessment, especially for sources below 5000 kelvins. A newer version of the CRI, R96, has been developed, but it has not replaced the better-known Ra general color rendering index.
History
Researchers use daylight as the benchmark to which to compare color rendering of electric lights. In 1948, daylight was described as the ideal source of illumination for good color rendering because "it displays a great variety of colours, makes it easy to distinguish slight shades of colour, and the colours of objects around us obviously look natural".Around the middle of the 20th century, color scientists took an interest in assessing the ability of artificial lights to accurately reproduce colors. European researchers attempted to describe illuminants by measuring the spectral power distribution in "representative" spectral bands, whereas their North American counterparts studied the colorimetric effect of the illuminants on reference objects.
The CIE assembled a committee to study the matter and accepted the proposal to use the latter approach, which has the virtue of not needing spectrophotometry, with a set of Munsell samples. Eight samples of varying hue would be alternately lit with two illuminants, and the color appearance compared. Since no color appearance model existed at the time, it was decided to base the evaluation on color differences in a suitable color space, CIEUVW. In 1931, the CIE adopted the first formal system of colorimetry, which is based on the trichromatic nature of the human visual system. CRI is based upon this system of colorimetry.
To deal with the problem of having to compare light sources of different correlated color temperatures, the CIE settled on using a reference black body with the same color temperature for lamps with a CCT of under 5000 K, or a phase of CIE standard illuminant D otherwise. This presented a continuous range of color temperatures to choose a reference from. Any chromaticity difference between the source and reference illuminants were to be abridged with a von Kries-type chromatic adaptation transform.
Test method
The CRI is calculated by comparing the color rendering of the test source to that of a "perfect" source, which is a black body radiator for sources with correlated color temperatures under 5000 K, and a phase of daylight otherwise. Chromatic adaptation should be performed so that like quantities are compared. The Test Method needs only colorimetric, rather than spectrophotometric, information.- Using the 2° standard observer, find the chromaticity co-ordinates of the test source in the CIE 1960 color space.
- Determine the correlated color temperature of the test source by finding the closest point to the Planckian locus on the chromaticity diagram.
- If the test source has a CCT < 5000 K, use a black body for reference, otherwise use CIE standard illuminant D. Both sources should have the same CCT.
- Ensure that the chromaticity distance of the test source to the Planckian locus is under 5.4×10−3 in the CIE 1960 UCS. This ensures the meaningfulness of the result, as the CRI is only defined for light sources that are approximately white.
- Illuminate the first eight standard samples, from the fifteen listed below, alternately using both sources.
- Using the 2° standard observer, find the co-ordinates of the light reflected by each sample in the CIE 1964 color space.
- Chromatically adapt each sample by a von Kries transform.
- For each sample, calculate the Euclidean distance between the pair of co-ordinates.
- Calculate the special CRI using the formula
- Find the general CRI by calculating the arithmetic mean of the special CRIs.
Chromatic adaptation
uses this von Kries chromatic transform equation to find the corresponding color for each sample. The mixed subscripts refer to the inner product of the test illuminant spectrum and the spectral reflexivity of sample i:where subscripts r and t refer to reference and test light sources respectively.
Test color samples
Name | Appr. Munsell | Appearance under daylight | Swatch |
TCS01 | 7,5 R 6/4 | Light greyish red | |
TCS02 | 5 Y 6/4 | Dark greyish yellow | |
TCS03 | 5 GY 6/8 | Strong yellow green | |
TCS04 | 2,5 G 6/6 | Moderate yellowish green | |
TCS05 | 10 BG 6/4 | Light bluish green | |
TCS06 | 5 PB 6/8 | Light blue | |
TCS07 | 2,5 P 6/8 | Light violet | |
TCS08 | 10 P 6/8 | Light reddish purple | |
TCS09 | 4,5 R 4/13 | Strong red | |
TCS10 | 5 Y 8/10 | Strong yellow | |
TCS11 | 4,5 G 5/8 | Strong green | |
TCS12 | 3 PB 3/11 | Strong blue | |
TCS13 | 5 YR 8/4 | Light yellowish pink | |
TCS14 | 5 GY 4/4 | Moderate olive green |
As specified in, the original test color samples are taken from an early edition of the Munsell Atlas. The first eight samples, a subset of the eighteen proposed in, are relatively low saturated colors and are evenly distributed over the complete range of hues. These eight samples are employed to calculate the general color rendering index. The last six samples provide supplementary information about the color rendering properties of the light source; the first four for high saturation, and the last two as representatives of well-known objects. The reflectance spectra of these samples may be found in, and their approximate Munsell notations are listed aside.
R96a method
In the CIE's 1991 Quadrennial Meeting, Technical Committee 1-33 was assembled to work on updating the color rendering method, as a result of which the R96a method was developed. The committee was dissolved in 1999, releasing, but no firm recommendations, partly due to disagreements between researchers and manufacturers.The R96a method has a few distinguishing features:
- [|A new set of test color samples]
- Six reference illuminants: D65, D50, black bodies of 4200 K, 3450 K, 2950 K, and 2700 K.
- A new chromatic adaptation transform: CIECAT94.
- Color difference evaluation in CIELAB.
- Adaptation of all colors to D65.
New test color samples
As discussed in, recommends the use of a ColorChecker chart owing to the obsolescence of the original samples, of which only metameric matches remain. In addition to the eight ColorChart samples, two skin tone samples are defined. Accordingly, the updated general CRI is averaged over ten samples, not eight as before. Nevertheless, has determined that the patches in give better correlations for any color difference than the ColorChecker chart, whose samples are not equally distributed in a uniform color space.Example
The CRI can also be theoretically derived from the SPD of the illuminant and samples, since physical copies of the original color samples are difficult to find. In this method, care should be taken to use a sampling resolution fine enough to capture spikes in the SPD. The SPDs of the standard test colors are tabulated in 5 nm increments, so it is suggested to use interpolation up to the resolution of the illuminant's spectrophotometry.Starting with the SPD, let us verify that the CRI of reference illuminant F4 is 51. The first step is to determine the tristimulus values using the 1931 standard observer. Calculation of the inner product of the SPD with the standard observer's color matching functions yields = . From this follow the xy chromaticity values:
The next step is to convert these chromaticities to the CIE 1960 UCS in order to be able to determine the CCT:
Examining the CIE 1960 UCS reveals this point to be closest to 2938 K on the Planckian locus, which has a coordinate of. The distance of the test point to the locus is under the limit, so we can continue the procedure, assured of a meaningful result:
We can verify the CCT by using McCamy's approximation algorithm to estimate the CCT from the xy chromaticities:
where.
Substituting yields n = 0.4979 and CCTest. = 2941 K, which is close enough. Since 2940 < 5000, we select a Planckian radiator of 2940 K as the reference illuminant.
The next step is to determine the values of the test color samples under each illuminant in the CIEUVW color space. This is done by integrating the product of the CMF with the SPDs of the illuminant and the sample, then converting from CIEXYZ to CIEUVW :
Illuminant | Illuminant | TCS1 | TCS2 | TCS3 | TCS4 | TCS5 | TCS6 | TCS7 | TCS8 |
Reference | U | 39.22 | 17.06 | −13.94 | −40.83 | −35.55 | −23.37 | 16.43 | 44.64 |
Reference | V | 2.65 | 9.00 | 14.97 | 7.88 | −2.86 | −13.94 | −12.17 | −8.01 |
Reference | W | 62.84 | 61.08 | 61.10 | 58.11 | 59.16 | 58.29 | 60.47 | 63.77 |
CIE FL4 | U | 26.56 | 10.71 | −14.06 | −27.45 | −22.74 | −13.99 | 9.61 | 25.52 |
CIE FL4 | V | 3.91 | 11.14 | 17.06 | 9.42 | −3.40 | −17.40 | −15.71 | -10.23 |
CIE FL4 | W | 63.10 | 61.78 | 62.30 | 57.54 | 58.46 | 56.45 | 59.11 | 61.69 |
CIE FL4 | U | 26.34 | 10.45 | −14.36 | −27.78 | −23.10 | −14.33 | 9.37 | 25.33 |
CIE FL4 | V | 4.34 | 11.42 | 17.26 | 9.81 | −2.70 | −16.44 | −14.82 | −9.47 |
CIE FL4 | W | 63.10 | 61.78 | 62.30 | 57.54 | 58.46 | 56.45 | 59.11 | 61.69 |
From this we can calculate the color difference between the chromatically adapted samples and those illuminated by the reference. The special CRI is simply.
TCS1 | TCS2 | TCS3 | TCS4 | TCS5 | TCS6 | TCS7 | TCS8 | |
12.99 | 7.07 | 2.63 | 13.20 | 12.47 | 9.56 | 7.66 | 19.48 | |
Ri | 40.2 | 67.5 | 87.9 | 39.3 | 42.6 | 56.0 | 64.8 | 10.4 |
Finally, the general color rendering index is the mean of the special CRIs: 51.
Typical values
A reference source, such as blackbody radiation, is defined as having a CRI of 100. This is why incandescent lamps have that rating, as they are, in effect, almost blackbody radiators. The best possible faithfulness to a reference is specified by CRI = 100, while the very poorest is specified by a CRI below zero. A high CRI by itself does not imply a good rendition of color, because the reference itself may have an imbalanced SPD if it has an extreme color temperature.Special value: R9
Ra is the average value of R1–R8, other values from R9 to R15 are missing in Ra calculation, including R9 "saturated red", R13 "skin color ", and R15 "skin color ", which are all difficult colors to faithfully reproduce. R9 is a vital index in high-CRI lighting, as many applications require red lights, such as film and video lighting, medical lighting, art lighting, etc. However, in general CRI calculation, R9 is not included.R9 is one of the numbers of Ri refers to test color samples, which is one score in extended CRI. It is the number rates the light source’s color revealing ability towards TCS 09. And it describes the specific ability of light to accurately reproduce the red color of objects. Many lights manufacturers or retailers do not point out the score of R9, while it is a vital value to evaluate the color rendition performance for film and video lighting, as well as any applications that need high CRI value. So, generally, it is regarded as a supplement of color rendering index when evaluating a high-CRI light source.
R9 value, TCS 09, or in other words, the red color is the key color for many lighting applications, such as film and video lighting, textile printing, image printing, skin tone, medical lighting, and so on. Besides, many other objects which are not in red color, but actually consists of different colors including red color. For instance, the skin tone is impacted by the blood under the skin, which means that the skin tone also includes red color, although it looks much like close to white or light yellow. So, if the R9 value is not good enough, the skin tone under this light will be more paleness or even greenish in your eyes or cameras.
Criticism
Ohno and others have criticized CRI for not always correlating well with subjective color rendering quality in practice, particularly for light sources with spiky emission spectra such as fluorescent lamps or white LEDs. Another problem is that the CRI is discontinuous at 5000 K, because the chromaticity of the reference moves from the Planckian locus to the CIE daylight locus. identify several other issues, which they address in their Color Quality Scale :- The color space in which the color distance is calculated is obsolete and nonuniform. Use CIELAB or CIELUV instead.
- The chromatic adaptation transform used is inadequate. Use CMCCAT2000 or CIECAT02 instead.
- Calculating the arithmetic mean of the errors diminishes the contribution of any single large deviation. Two light sources with similar CRI may perform significantly differently if one has a particularly low special CRI in a spectral band that is important for the application. Use the root-mean-square deviation instead.
- The metric is not perceptual; all errors are equally weighted, whereas humans favor certain errors over others. A color can be more saturated or less saturated without a change in the numerical value of ∆Ei, while in general a saturated color is experienced as being more attractive.
- A negative CRI is difficult to interpret. Normalize the scale from 0 to 100 using the formula.
- The CRI cannot be calculated for light sources that do not have a CCT.
- Eight samples are not enough since manufacturers can optimize the emission spectra of their lamps to reproduce them faithfully, but otherwise perform poorly. Use more samples.
- The samples are not saturated enough to pose difficulty for reproduction.
- CRI merely measures the faithfulness of any illuminant to an ideal source with the same CCT, but the ideal source itself may not render colors well if it has an extreme color temperature, due to a lack of energy at either short or long wavelengths. Weight the result by the ratio of the gamut area of the polygon formed by the fifteen samples in CIELAB for 6500 K to the gamut area for the test source. 6500 K is chosen for reference since it has a relatively even distribution of energy over the visible spectrum and hence high gamut area. This normalizes the multiplication factor.
developed a psychophysical experiment in order to evaluate light quality of LED lightings. It is based on colored samples used in the "Color Quality Scale". Predictions of the CQS and results from visual measurements were compared.
"reviews the applicability of the CIE color rendering index to white LED light sources based on the results of visual experiments". Chaired by Davis, CIE TC 1-69 is currently investigating "new methods for assessing the color rendition properties of white-light sources used for illumination, including solid-state light sources, with the goal of recommending new assessment procedures by March, 2010".
For a comprehensive review of alternative color rendering indexes see.
reviewed several alternative quality metrics and compared their performance based on visual data obtained in nine psychophysical experiments. It was found that a geometric mean of the GAI index and the CIE Ra correlated best with naturalness, while a color quality metric based on memory colors correlated best for preference. The differences in performance of these metrics with the other tested metrics were found to be statistically significant with p < 0.0001.
performed psychophysical experiments and concluded that people’s judgments of naturalness and overall preference could not be predicted with a single measure, but required the joint use of a fidelity-based measure and a gamut-based measure. They carried out further experiments in real offices evaluating various spectra generated for combination existing and proposed colour rendering metrics.
Film and video high-CRI LED lighting
Problems have been encountered attempting to use LED lighting on film and video sets. The color spectra of LED lighting primary colors does not match the expected color wavelength bandpasses of film emulsions and digital sensors. As a result, color rendition can be completely unpredictable in optical prints, transfers to digital media from film, and video camera recordings. This phenomenon with respect to motion picture film has been documented in an LED lighting evaluation series of tests produced by the Academy of Motion Picture Arts and Sciences scientific staff.To that end, various other metrics such as the TLCI have been developed to replace the human observer with a camera observer. Similar to the CRI, the metric measures quality of a light source as it would appear on camera on a scale from 0 to 100. Some manufacturers say that their products have TLCI values of up to 99.