Answer to reset
An Answer To Reset is a message output by a contact Smart Card conforming to ISO/IEC 7816 standards, following electrical reset of the card's chip by a card reader. The ATR conveys information about the communication parameters proposed by the card, and the card's nature and state.
By extension, ATR often refers to a message obtained from a Smart Card in an early communication stage; or from the card reader used to access that card, which may transform the card's message into an ATR-like format.
The presence of an ATR is often used as a first indication that a Smart Card appears operative, and its content examined as a first test that it is of the appropriate kind for a given usage.
Contact Smart Cards communicate over a signal named Input/Output either synchronously or asynchronously. The two modes are exclusive in a given communication session, and most cards are built with support for a single mode. Microprocessor-based contact Smart Cards are mostly of the asynchronous variety, used for all Subscriber Identity Modules for mobile phones, those bank cards with contacts that conform to EMV specifications, all contact Java Cards, and Smart Cards for pay television. Memory-only cards are generally of the synchronous variety.
ATR under asynchronous and synchronous transmission have entirely different form and content. The ATR in asynchronous transmission is precisely normalized, and relatively complex to parse.
Some Smart Cards send different ATR depending on if the reset is the first since power-up or not.
Note: Answer To Reset should not be confused with ATtRibute REQuest and ATtRibute RESponse of NFC, also abbreviated ATR. ATR_RES conveys information about the communication parameters supported, as does Answer To Reset, but its structure is different.
ATR in asynchronous transmission
The standard defining the ATR in asynchronous transmission is ISO/IEC 7816-3. Subsets of the full ATR specification are used for some Smart Card applications, e.g. EMV.Physical form and timing at the card/reader interface
In asynchronous transmission, the ATR is transmitted by a card to a reader as characters, encoded as bits over the contact designated I/O, with a nominal bit duration denoted Elementary Time Unit, equal during the whole ATR to 372 periods of the clock signal supplied by the reader on the CLK contact. The I/O line is by default at a H state, and a transition to L state, denoted leading edge, defines the start of a character. The leading edge of the first character occurs between 400 and 40 000 clock cycles after the reader changed the RST contact from L to H.Each characters comprises a start bit at L state, 8 data bits, 1 parity bit, followed by a delay at the H state such that the leading edge of characters in the ATR is at least 12 ETU, with maximum designated Waiting Time WT = 9 600 ETU during the whole ATR. The value of the byte encoded by a character is defined according to conventions determined by the first character of the ATR, designated TS.
The end of the physical ATR between card and reader can be determined by the reader using analysis on the fly of the values of TS, T0, and any TDi, or/and on the basis of WT. The later method incurs an extra delay. EMV also allows the reader to consider that the ATR must be over after 20 160 ETU counted from the leading edge of TS.
Note: When communicating in asynchronous mode with an ISO/IEC 7816-3 contact Smart Card using a serial interface device operating per direct convention, it can be set to 8 bits, 1 even parity bit, 2 stop bits ; during the ATR, the baud rate should be 1/372 of the clock frequency received by the card. There will normally be no parity error or framing error. The first byte received is if the card operates in direct convention, if the cards operates in inverse convention, in which case the polarity and order of all 8 bits of each byte going through the serial interface device should be reversed, which in particular will change the first byte to.
Historical note: provision for cards that use an internal clock source and a fixed ETU of 1/9 600 second during ATR existed in ISO/IEC 7816-3:1989, and was removed from the 1997 edition onwards.
General structure
The ATR proceeds in five steps: initial character TS; format byte T0; interface bytes TAi, TBi, TCi, TDi ; historical bytes Ti, and the check byte TCK. There are a total of 2 to 33 characters including TS.Name | Defines | Encodes | Present when |
TS | Bit order and polarity | ||
T0 | Number of Ti, presence of TA1..TD1 | K in | |
TA1 | Maximum clock frequency, proposed bit duration | FI ↦ Fi and fmax; DI ↦ Di | 5th bit of T0 is |
TB1 | Deprecated: VPP requirements | PI1 ↦ P, II ↦ I | 6th bit of T0 is |
TC1 | Extra delay between bytes required by card | N ↦ EGT ↦ GT | 7th bit of T0 is |
TD1 | First offered transmission protocol, presence of TA2..TD2 | T in | 8th bit of T0 is |
TA2 | Specific protocol and parameters to be used after the ATR | T in | 5th bit of TD1 is |
TB2 | Deprecated: VPP precise voltage requirement | PI2 ↦ P | 6th bit of TD1 is |
TC2 | Maximum waiting time for protocol T = 0 | WI ↦ WT | 7th bit of TD1 is |
TD2 | A supported protocol or more global parameters, presence of TA3..TD3 | T in | 8th bit of TD1 is |
TAi | For T = 1 : maximum block size the card can receive If T = 15 : supported supply voltages and low power modes | IFSC X; Y | 5th bit of TDi-1 is |
TBi | For T = 1 : maximum delays between characters If T = 15 : use of SPU contact C6 | CWI ↦ CWT; BWI ↦ BWT | 6th bit of TDi-1 is |
TCi | For T = 1 : type of error detection code used | 7th bit of TDi-1 is | |
TDi | A supported protocol or more global parameters, presence of TAi+1..TDi+1 | T in | 8th bit of TDi-1 is |
T1 | The format of historical bytes Ti | K ≥ 1 | |
Ti | Historical bytes indicating operating characteristics, per ISO/IEC 7616-4 when T1 is, or, | K ≥ i | |
TCK | Allow detection of accidental transmission error | T in any of the TDi bytes is not 0 |
The signification given is assuming i > 2, and i-1 is the only j with 1 < j < i such that TDj encodes the stated value of T. When that T is in range , the signification of the byte applies only to the corresponding protocol. When that T = 15, the signification applies regardless of protocol.
The initial character TS is always physically present, but is excluded of the Answer-to-Reset in the definition given by ISO/IEC 7816-3:2006: the value of the byte string encoded in the sequence of characters following the initial character TS. ISO/IEC 7816-4:2005 concurs, stating that TS is a character or synchronization pattern, not a byte. However practice is still to consider that TS is part of the ATR, as it was in ISO/IEC 7816-3:1997 and former. In particular, the ATR returned by PC/SC card readers and software stacks includes TS as the first byte, with value or.
Initial character TS
The initial character TS encodes the convention used for encoding of the ATR, and further communications until the next reset. In direct convention, bits with logic value are transferred as a High voltage ; bits with logic value are transferred as L ; and least-significant bit of each data byte is first in the physical transmission by the card.For direct convention, TS is and encodes the byte.
For inverse convention, TS is and encodes the byte.
Bits in bytes following TS in the ATR, and further communications until the next reset, are numbered 1st to 8th from low-order to high-order, and their value noted or, regardless of the chronological order and electrical representation, defined by TS. The bit following the 8 data bits in these bytes is an even parity bit, that is such that there's an even number of bits among the 8 data bits and the parity bit.
TS also allows the card reader to confirm or determine the ETU, as one third of the delay between the first and second H-to-L transition in TS. This is optional, and the principal definition of ETU in the ATR of standard-compliant asynchronous Smart Cards is 372 periods of the clock received by the card.
Format byte T0
The Format byte T0 encodes in its 4 low-order bits the number K of historical bytes Ti, in range .It also encodes in its 4 high-order bits the presence of at most 4 other interface bytes: TA1 follow, in that order, if the 5th bit of T0 is.
Interface bytes TA''i'', TB''i'', TC''i'', TD''i''
Interface bytes TA1, TB1, TC1, TD1, TA2, TB2, TC2, TD2, TA3, TB3,.. are all optional, and encode communication parameters and protocols that the card propose to use.Interface bytes come in three kinds: global interface bytes apply to all protocols; specific interface bytes apply to a specific protocol; and structural interface bytes introduce further interface bytes, and protocols.
Interface byte TA1
Interface byte TA1, if present, is global, and encodes the maximum clock frequency fmax supported by the card, and the number of clock periods per ETU that it suggests to use after the ATR, expressed as the ratio Fi/Di of two integers. When TA1 is absent, it's assumed default value is, corresponding to fmax = 5 MHz, Fi = 372, Di = 1.The 4 low-order bits of TA1 encode Di as:
4th to 1st bits | ||||||||||||||||
Di | RFU | 1 | 2 | 4 | 8 | 16 | 32 | 64 | 12 | 20 | RFU | RFU | RFU | RFU | RFU | RFU |
This was RFU in ISO/IEC 7816-3:1997 and former. Some card readers or drivers may erroneously reject cards using this value. Some PC/SC readers, as a workaround to said driver behavior, clear the 1st bit of TA1 when its 4 low-order bits encode 7, and accordingly adjust TCK, unless they have received a special command.
The 4 high-order bits of TA1 encode fmax and Fi as:
8th to 5th bits | ||||||||||||||||
Fi | 372 | 372 | 558 | 744 | 1 116 | 1 488 | 1 860 | RFU | RFU | 512 | 768 | 1 024 | 1 536 | 2 048 | RFU | RFU |
fmax | 4 | 5 | 6 | 8 | 12 | 16 | 20 | — | — | 5 | 7.5 | 10 | 15 | 20 | — | — |
Note:EMV, and ISO/IEC 7816-3 before the 2006 edition, additionally use the notation DI for the low-order 4 bits of TA1. DI thus encodes Di, and FI encodes Fi and fmax.
Note: EMV's notation uses D where ISO/IEC 7816-3 uses Di.
Example: TA1 = = , in which FI is and DI is, encodes fmax = 10 MHz, Fi = 1024, Di = 16, thus Fi/Di = 1024/16 = 64. This is inviting the card reader to take the necessary steps to reduce the ETU to 64 clock cycles per ETU and increase the clock frequency up to 10 MHz.
Interface byte TB1
TB1, if present, is global. The usage of TB1 is deprecated since the 2006 edition of the standard, which prescribes that cards should not include TB1 in the ATR, and readers shall ignore TB1 if present. EMV still requires that the card includes TB1 = , and that remains common practice; doing so explicitly indicates that the card does not use the dedicated contact C6 for the purpose of supplying a programming voltage to the card; the cards might however use C6 for Standard or Proprietary Use, such as communicating with a NFC front end by the Single Wire Protocol. On the reader side, EMV requires making a warm ATR for cards with TB1 other than in the cold ATR, and handling any TB1 in a warm ATR as if it was.TB1 was previously indicating the programming voltage VPP and maximum programming current required by some cards on the dedicated contact C6 during programming of their EPROM memory. Modern Smart Cards internally generate the programming voltage for their EEPROM or Flash memory, and thus do not use VPP. In the 1997 and earlier editions of the standard:
- The low 5 bits of TB1 encode PI1; if TB2 is absent, PI1 = 0 indicates that the C6 contact is not connected in the card; PI1 in range encodes the value of VPP in Volt ; if TB2 is present, it supersedes the indication given by TB1 in the PI1 field, regarding VPP connection or voltage.
- The high bit of TB1 is reserved, shall be, and can be ignored by the reader.
- The 6th and 5th bits of TB1 encode the maximum programming current.
7th and 6th bits | ||||
Maximum programming current | 25 mA | 50 mA | RFU | RFU |
Interface byte TC1
TC1, if present, is global, and encodes the Extra Guard Time integer, from 0 to 255 ; otherwise, N = 0. N defines how much the Guard Time that the reader must apply varies from a baseline of 12 ETU.The Guard Time is the minimum delay between the leading edge of the previous character, and the leading edge of the next character sent.
Except when N is 255, the Guard Time is: GT = 12 ETU + R*N/f
where:
– f is the clock frequency being generated by the reader;
– R is some number of clock cycles, either:
– per ETU, R = F/D, if T = 15 is absent from the ATR;
– defined by TA1, R = Fi/Di, if T = 15 is present in the ATR.
N = 255 has a protocol-dependent meaning: GT = 12 ETU during PPS and protocol T = 0, GT = 11 ETU under protocol T = 1.
Except under protocol T = 1, the card transmits with a Guard Time of 12 ETU, irrespective of N.
Under protocol T = 1, the Guard Time defined by N is also the Character Guard Time, and applies to card and reader for characters sent in the same direction.
Note: The reader remains bound by the Guard Time GT defined by N when other prescriptions specify another minimum delay between leading edges of characters in different directions, even when that minimum is lower than GT.
Historical note: ISO/IEC 7816-3:1989 only defined that N code the EGT as a number of ETU, the method now used when T = 15 is absent from the ATR. With this convention, cards that allow negotiation of a reduced number of clock cycles per ETU after PPS must also allow a proportionally reduced number of clock cycles for the EGT, which does not match with a common EGT motivation: account for delays before the card can receive the next character. The 1997 edition of the standard introduced that when T = 15 is present in the ATR, N code the EGT as a multiple of the number of clock cycles per ETU coded by TA1, making the EGT effectively independent of the number of clocks cycles per ETU negotiated, while maintaining compatibility with former readers at least if they did not change the number of clock cycles per ETU.
Interface bytes TD''i''
Interfaces bytes TDi for i≥1, if present, are structural.TDi encodes in its 4 high-order bits the presence of at most 4 other interface bytes: TAi+1 follow, in that order, if the 5th bit of TDi is.
TDi encodes in its 4 low-order bits an integer T, in range . T = 15 is invalid in TD1, and in other TDi qualifies the following TAi+1 TBi+1, TCi+1, TDi+1 as global interface bytes. Other values of T indicates a protocol that the card is willing to use, and that TAi+1 TBi+1, TCi+1, TDi+1 are specific interface bytes applying only to that protocol. T = 0 is a character-oriented protocol. T = 1 is a block-oriented protocol. T in the range is RFU.
Historical note: provision for dynamically qualifying interface bytes as global using T = 15 did not exist in ISO/IEC 7816-3:1989.
Interface byte TA2
Interface byte TA2, if present, is global, and is named the specific mode byte.Presence of TA2 commands that the reader use specific mode as defined by TA2 and earlier global bytes, rather than negotiable mode when TA2 is absent.
TA2 encodes in its 4 low-order bits an integer T defining the protocol required by the card, in the convention used for TD1.
The 5th bit is to encodes that the required ETU duration is Fi/Di clock cycles as defined by TA1 ; or to indicate that the ETU duration is implicitly known.
The 6th and 7th bit are reserved for future use; indicates not used.
The 8th bit is to indicate that the card is unable to change the negotiable/specific mode ; or to indicate that card has that ability.
Historical note: Provision for specific mode did not exist in ISO/IEC 7816-3:1989. Back then, the interface character TA2 had no particular name or function, and was specific. ISO/IEC 7816-3:1997 introduced the specific mode and the specific mode byte, with interim note helping cards with specific mode byte TA2 in their ATR dealing with a reader that did not implement specific mode.
Interface byte TB2
TB2, if present, is global. The usage of TB2 is deprecated since the 2006 edition of the standard, which prescribes that cards should not include TB2 in the ATR, and readers shall ignore TB2 if present.In the 1997 edition of the standard, TB2 encode PI2, which when in range 50..250 encode VPP in increments of 0.1 V, and subsumes the coarser indication given by PI1 of TB1. Refer to that section for why modern Smart Cards have no use of VPP, and thus of TB2.
Historical note: Provision for TB2 did not exist in ISO/IEC 7816-3:1989, and was introduced because VPP = 12.5 V became a popular value in EEPROM technology, replacing 25 V and 21 V.
Historical bytes T''i''
Historical Characters Ti for i≥1, if present, typically hold Information about the Card Builder, Type of Card, Version number and the State of the Card.Check byte TCK
The ChecK byte allows a check of the integrity of the data in the ATR. If present, TCK is the Exclusive OR of the bytes in the ATR from T0 to TCK.TCK shall be present if and only if any of the TDi present in the ATR encodes a value of T other than 0.
That rule for TCK presence is per ISO/IEC 7816-3:1989. The later ISO/IEC 7816-3:1997 and ISO/IEC 7816-3:2006 concur, at least whenever TA2 is absent or encodes the same T as TD1. Common practice is to apply that rule, notwithstanding the contradictory prescription in EMV 4.3 Book 1, section 8.3.4, that The ATR shall not contain TCK if T = 0 only is to be used, instead reading that prescription as is if it ended in if T = 0 only is indicated.
ATR in synchronous transmission
The official reference defining the ATR in synchronous transmission is the ISO/IEC 7816-10 standard.The ATR starts with a header of 32 bits organized into 4 bytes, denoted H1 to H4. H1 codes the protocol, H2 codes parameters of the protocol. Little more is standardized.